4.7 Article

Simulation Models of Misclassification Error for Single Thresholds of High-Sensitivity Cardiac Troponin I Due to Assay Bias and Imprecision

期刊

CLINICAL CHEMISTRY
卷 63, 期 2, 页码 585-592

出版社

OXFORD UNIV PRESS INC
DOI: 10.1373/clinchem.2016.265058

关键词

-

资金

  1. Abbott Laboratories
  2. Abbott Point of Care
  3. Beckman Coulter
  4. Ortho Clinical Diagnostics
  5. Roche Diagnostics
  6. Siemens Healthcare Diagnostics
  7. Canadian Institutes of Health Research

向作者/读者索取更多资源

BACKGROUND: Clinical outcome studies for cardiac troponins (cTn) are expensive and difficult to design owing to variation in patients, in the assays, and in the incidence of different types of myocardial infarction (MI). To overcome these difficulties, simulation models were used to estimate the rate of misclassification error for MI and risk prediction resulting from assay bias and imprecision. METHODS: Finite mixture analysis of Abbott high sensitivity cTnI (hs-cTnI) results at time 0 h in patients presenting early with acute coronary syndrome (ACS) symptoms to the emergency department (ED) [n = 145, Reducing the Time Interval for Identifying New Guideline (RING) study] allowed derivation of a simulation data set (n = 10 000). hs-cTnI concentrations were modified by addition of bias or imprecision error. The percentage of all 10 000 modified hs-cTnI results that were misclassified for MI at thresholds of 2, 5, 26.2, and 52 ng/L was determined by Monte Carlo simulation. Analyses were replicated with an all-comer emergency department (ED) population (n = 1137) ROMI (Optimum Troponin Cutoffs for ACS in the ED) study. RESULTS: In the RING study, simulation at 26.2-ng/L (99th percentile) and 52-ng/L thresholds were affected by both bias +/- 2 ng/L and imprecision (10%-20%) and had misclassification rates of 0.4% to 0.6%. Simulations at the +/- 2-ng/L and 5-ng/L thresholds were only affected by bias. Misclassification rates at bias of +/- 1 ng/L were 10% for the +/- 2-ng/L threshold, and 5% for the 5-ng/L threshold. CONCLUSIONS: Simulation models predicted that hscTnI results are seldom misclassified (<1% of patients) when interpretative thresholds are near or exceed the overall 99th percentile. However, simulation models also predicted that low hs-cTnI results, as recommended in guidelines, are prone to misclassification of 5%-10% of patients. (C) 2016 American Association for Clinical Chemistry

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据