4.6 Article

Biomechanical Comparison of Periprosthetic Femoral Fracture Risk in Three Femoral Components in a Sawbone Model

期刊

JOURNAL OF ARTHROPLASTY
卷 36, 期 1, 页码 387-394

出版社

CHURCHILL LIVINGSTONE INC MEDICAL PUBLISHERS
DOI: 10.1016/j.arth.2020.07.061

关键词

periprosthetic fracture; hip arthroplasty; cemented stem failure; biomechanical testing; Sawbone model

资金

  1. University Hosptials of Leicester NHS Trust Charity, United Kingdom

向作者/读者索取更多资源

The research compared the biomechanics of different types of hip arthroplasty implants in a composite model, finding that the CPT and C-Stem implants fractured at lower rotation and torque values and with less comminution. Therefore, the CPT implant carries a higher risk of PPFs.
Background: The increasing use of orthopedic total hip arthroplasty implants has led to a consequent rise in the incidence of associated periprosthetic fractures (PPFs). Analysis of the National Joint Registry data showed the choice of cemented hip stem influenced the risk of a PPF occurring. However, the effect of implant design in relation to the risk of PPFs has not been investigated. Methods: The main objective is to compare the biomechanics of PPFs as a failure of the Exeter V40, CPT, and DePuy C-Stem stems in a composite Sawbone model to identify whether a difference in the risk of fracture exists between them. Twenty-six Sawbones were divided into 3 groups, cemented with the Stryker Exeter, Zimmer CPT, or DePuy C-Stem and then torqued to fracture. Results: When compared with the Exeter, the CPT- and C-Stem-implanted Sawbone models would sustain PPFs at a statistically significantly lower rotation to failure (20.1 degrees and 26.7 degrees vs 33.6 degrees, P < .01) and torque to failure (124 Nm and 143 Nm vs 174 Nm, P < .01) values. The energy release rate at failure for the Exeter was significantly higher than that for the CPT and C-Stem (61.2 Nm vs 21.8 Nm and 38.6 Nm, P < .01), which led to more comminution. Conclusion: The CPT- and C-Stem-implanted femurs, although fracturing earlier, fractured in a simple pattern with less comminution. The differences in stem design mean higher stress at the critical point of failure in the CPT implanted femur compared with the Exeter and DePuy, which is likely the reason behind the observed increased risk of PPFs with the CPT implant. (C) 2020 Elsevier Inc. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据