4.7 Article

Machine Segmentation of Pelvic Anatomy in MRI-Assisted Radiosurgery (MARS) for Prostate Cancer Brachytherapy

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.ijrobp.2020.06.076

关键词

-

向作者/读者索取更多资源

Purpose: To investigate machine segmentation of pelvic anatomy in magnetic resonance imaging (MRI)-assisted radiosurgery (MARS) for prostate cancer using prostate brachytherapy MRIs acquired with different pulse sequences and image contrasts. Methods and Materials: Two hundred 3-dimensional (3D) preimplant and postimplant prostate brachytherapy MRI scans were acquired with a T2-weighted sequence, a T2/T1-weighted sequence, or a T1-weighted sequence. One hundred twenty deep machine learning models were trained to segment the prostate, seminal vesicles, external urinary sphincter, rectum, and bladder using the MRI scans acquired with T2-weighted and T2/T1-weighted image contrast. The deep machine learning models consisted of 18 fully convolutional networks (FCNs) with different convolutional encoders. Both 2-dimensional and 3D U-Net FCNs were constructed for comparison. Six objective functions were investigated: cross-entropy, Jaccard distance, focal loss, and 3 variations of Tversky distance. The performance of the models was compared using similarity metrics, including pixel accuracy, Jaccard index, Dice similarity coefficient (DSC), 95% Hausdorff distance, relative volume difference, Matthews correlation coefficient, precision, recall, and average symmetrical surface distance. We selected the highest-performing architecture and investigated how the amount of training data, use of skip connections, and data augmentation affected segmentation performance. In addition, we investigated whether segmentation on T1-weighted MRI was possible with FCNs trained on only T2weighted and T2/T1-weighted image contrast. Results: Overall, an FCN with a DenseNet201 encoder trained via cross-entropy minimization yielded the highest combined segmentation performance. For the 53 3D test MRI scans acquired with T2-weighted or T2/T1-weighted image contrast, the DSCs of the prostate, external urinary sphincter, seminal vesicles, rectum, and bladder were 0.90 +/- 0.04, 0.70 +/- 0.15, 0.80 +/- 0.12, 0.91 +/- 0.06, and 0.96 +/- 0.04, respectively, after model fine-tuning. For the 5 T1-weighted images, the DSCs of these organs were 0.82 +/- 0.07, 0.17 +/- 0.15, 0.46 +/- 0.21, 0.87 +/- 0.06, and 0.88 +/- 0.05, respectively. Conclusions: Machine segmentation of the prostate and surrounding anatomy on 3D MRIs acquired with different pulse sequences for MARS low-dose-rate prostate brachytherapy is possible with a single FCN. +/- 2020 Elsevier Inc. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据