4.1 Article

Distance and near visual performance in pseudophakic eyes with simulated spherical and astigmatic blur

期刊

CLINICAL AND EXPERIMENTAL OPTOMETRY
卷 99, 期 2, 页码 127-134

出版社

TAYLOR & FRANCIS LTD
DOI: 10.1111/cxo.12350

关键词

pseudophakia; astigmatism; visual acuity; reading

向作者/读者索取更多资源

Purpose Increased depth-of-focus after cataract surgery is dependent on various ocular characteristics, including refractive astigmatism. This work studied the influence of meridional blur produced by astigmatism, and spherical blur, on distance and near visual performance in pseudophakic eyes. Methods Visual performance was assessed monocularly in 59 pseudophakes (mean +/- standard deviation, 66.9 +/- 7.53 years) at distance (3.0 m) and near (0.33 m) using high- (HC: 94%) and low-contrast (LC: 10%) visual acuity (VA) charts. Reading performance (maximum reading speed [MRS], threshold print size [TPS] and reading acuity [RA]) was evaluated at near using a reading chart. Four refractive conditions at distance and near were monocularly simulated using the following trial lenses: distance (in-focus: +/- 0.00 DS, with-the-rule [WTR] astigmatism: +2.00 x 180; against-the-rule [ATR] astigmatism: +2.00 x 90; spherical defocus: +1.00 DS) and near (in-focus: +3.00 DS, WTR astigmatism: +2.00 x 180; ATR astigmatism: +2.00 x 90, spherical blur: +/- 0.00 DS). Results Distance high- and low-contrast VA were degraded by spherical and astigmatic blur in comparison to the distance in-focus condition (p < 0.001 for all), with astigmatism in either of the forms being more harmful than spherical blur (p < 0.001 for all). At near, best HC- and LCVA were attained with full near correction (p < 0.001 for all) followed by the ATR and WTR astigmatism. For all conditions, the VA measured was independent of whether the astigmatism was WTR or ATR. However, MRS was higher with +3.00 DS and ATR astigmatism compared to the other conditions. RA and TPS significantly strengthened the weak pattern seen with HCVA at near, with ATR astigmatism allowing significantly better RA and TPS than WTR astigmatism (p < 0.001 for all). Conclusions Simple myopic astigmatism improved near visual performance in pseudophakic eyes at the expense of some deterioration in distance performance. ATR astigmatism degraded VA at distance marginally more than WTR astigmatism and provided a marginally better VA at near. However, the benefit at near was more explicit when measured by reading performance, confirming the role of blur orientation on visual performance.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.1
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据