4.7 Article

Effective Measures to Improve Current Collection Quality for Double Pantographs and Catenary Based on Wave Propagation Analysis

期刊

IEEE TRANSACTIONS ON VEHICULAR TECHNOLOGY
卷 69, 期 6, 页码 6299-6309

出版社

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TVT.2020.2985382

关键词

Wires; Finite element analysis; Damping; Propagation; Numerical models; Force; Europe; Pantograph-catenary interaction; double-pantographs operation; FEM; wave propagation; optimization

资金

  1. National Nature Science Foundation of China [U1734202, 51977182]

向作者/读者索取更多资源

The pantograph installed on the train roof is responsible for collecting the electrical energy via the sliding contact with the catenary constructed along the railroad. To enhance the carrying capacity of the high-speed train, multiple pantographs are normally mounted on the EMU (Electrical Multiple Unit train) to interact simultaneously with the catenary. Especially in China, the double pantographs-catenary interaction is gradually becoming the mainstream in the newly built high-speed network. The biggest challenge of double-pantograph operation is the deterioration of the current collection quality of the trailing pantograph. The mechanical wave excited by the leading pantograph propagates along the contact wire and disturbs the trailing pantograph. This paper attempts to propose effective measures to improve the current collection quality of the trailing pantograph. To improve the understanding of the wave propagation in the contact wire excited by two pantographs, the double pantographs-catenary model is established using a FEM (Finite Element Method) approach. Through the analysis of the contact wire uplift response excited by a single moving force, the optimal interval of double pantographs is discussed. The results indicate that the bad interval appears at the velocity peak of the contact wire uplift, whereas, the good interval appears at the valley value of the contact wire uplift velocity. Based on this idea, the formula of optimal interval of double pantographs is proposed, and its validity is verified using the parameters of the European and China high-speed networks. Then the damper is introduced to the steady arm to reduce the wave intensity. The simulation results show that the slight steady arm damping has a positive effect on the performance of the double pantographs-catenary interaction.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据