4.7 Article

NIR-II/NIR-I Fluorescence Molecular Tomography of Heterogeneous Mice Based on Gaussian Weighted Neighborhood Fused Lasso Method

期刊

IEEE TRANSACTIONS ON MEDICAL IMAGING
卷 39, 期 6, 页码 2213-2222

出版社

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TMI.2020.2964853

关键词

Fluorescence molecular tomography; NIR-II; NIR-I; GWNFL method

资金

  1. National Key Research and Development Program of China [2017YFA0205200, 2016YFC0102600]
  2. National Natural Science Foundation of China (NSFC) [81930053, 61622117, 81671759, 81227901]
  3. Beijing Natural Science Foundation [JQ19027]
  4. Beijing Nova Program [Z181100006218046]
  5. Scientific Instrument Developing Project of the Chinese Academy of Sciences [YZ201672]
  6. Chinese Academy of Sciences [GJJSTD20170004]
  7. Key Research Program of the Chinese Academy of Sciences [KGZD-EW-T03]
  8. Innovative Research Team of High-Level Local Universities in Shanghai

向作者/读者索取更多资源

Fluorescence molecular tomography (FMT), which can visualize the distribution of fluorescence biomarkers, has become a novel three-dimensional noninvasive imaging technique for in vivo studies such as tumor detection and lymph node location. However, it remains a challenging problem to achieve satisfactory reconstruction performance of conventional FMT in the first near-infrared window (NIR-I, 700-900nm) because of the severe scattering of NIR-I light. In this study, a promising FMT method for heterogeneous mice was proposed to improve the reconstruction accuracy using the second near-infrared window (NIR-II, 1000-1700nm), where the light scattering significantly reduced compared with NIR-I. The optical properties of NIR-II were analyzed to construct the forward model for NIR-II FMT. Furthermore, to raise the accuracy of solution of the inverse problem, we proposed a novel Gaussian weighted neighborhood fused Lasso (GWNFL) method. Numerical simulation was performed to demonstrate the outperformance of GWNFL compared with other algorithms. Besides, a novel NIR-II/NIR-I dual-modality FMT system was developed to contrast the in vivo reconstruction performance between NIR-II FMT and NIR-I FMT. To compare the reconstruction performance of NIR-II FMT with traditional NIR-I FMT, numerical simulations and in vivo experiments were conducted. Both the simulation and in vivo results showed that NIR-II FMT outperformed NIR-I FMT in terms of location accuracy and spatial overlap index. It is believed that this study could promote the development and biomedical application of NIR-II FMT in the future.