4.4 Article

Non-destructive Monitoring ofStaphylococcus aureusBiofilm by Surface-Enhanced Raman Scattering Spectroscopy

期刊

FOOD ANALYTICAL METHODS
卷 13, 期 9, 页码 1710-1716

出版社

SPRINGER
DOI: 10.1007/s12161-020-01792-6

关键词

Staphylococcus aureus; Biofilm; Surface-enhanced Raman scattering (SERS); Crystal violet (CV) assay; Confocal laser scanning microscopy (CLSM)

资金

  1. National Key R&D Program of China [2018YFC1602300]
  2. Natural Science Foundation of Jiangsu Province [BK20171139]
  3. China Postdoctoral Science Foundation [2018 M642165]
  4. Yangtze River Delta Project of Shanghai [18395810200]
  5. National first-class discipline program of Food Science and Technology [JUFSTR20180509]

向作者/读者索取更多资源

Biofilms are organized bacterial communities embedded in extracellular polymeric matrices attached to living or abiotic surfaces. Eradicating biofilms completely is challenging and leads to repeated pollution. Thus, development of on-site and rapid biofilm detection methods is necessary. Various approaches for measuring biofilm formation have been implemented over the last decade. These include the crystal violet (CV) assay and confocal laser scanning microscopy (CLSM). However, the existing approaches are associated with issues, such as complexity and length of analysis. Consequently, in this work, a novel and rapid detection technique, specifically surface-enhanced Raman scattering (SERS), was investigated for the measurement of theStaphylococcus aureusbiofilm formation. After 5, 7, 9, 11, and 13 days of culture in simulated pipes, the biofilm growth was analyzed by SERS, CV assay, and CLSM. The study revealed that the SERS approach gave optimal results following linear fitting at the relative peak intensities ofI(1172 cm)(-1)/I(722 cm)(-1)andI(1384 cm)(-1)/I-722 cm(-1), with theR(2)values of 0.9576 and 0.9640. It was established that the two characteristic Raman peaks reflected the change of biofilm more adequately. The SERS method was compared with the CV assay and CLSM by Pearson correlation analysis. In addition to a good correlation between SERS and CV assay (P< 0.05), a significant correlation between SERS and CLSM (P< 0.01) was determined. Moreover, the novel SERS method considerably shortened the detection time, eliminating the necessity for an elution step. Overall, the described technique is a reliable on-site and non-destructive biofilm formation detection method.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据