4.3 Article

Corneal Elevation, Power, and Astigmatism to Assess Toric Orthokeratology Lenses in Moderate-to-High Astigmats

期刊

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/ICL.0000000000000721

关键词

Corneal elevation; Astigmatism; Orthokeratology; Treatment zone; Tomography

资金

  1. Euclid Systems
  2. Novartis
  3. University of Houston Student Vision Research Support Grant
  4. NEI [P30 EY007551-31]

向作者/读者索取更多资源

The study on corneal shape and the relationship between peripheral elevation and central astigmatism in astigmatic individuals found a high correlation between central corneal astigmatism and peripheral elevation, suggesting that central corneal astigmatism may be a more expedient measure for clinical use. Additionally, the treatment area decreased as corneal astigmatism and elevation increased.
Objectives: Fitting philosophies for toric orthokeratology are based on elevation or corneal astigmatism, but it is unclear which is more effective. The purpose of this analysis was to further understand corneal shape and the relationship between peripheral elevation and central astigmatism in moderate-to-high astigmats. Methods: Corneal tomography was measured three times on the right eyes of 25 moderate-to-high refractive myopic astigmatic adults. Corneal astigmatism and elevation were calculated at 4-, 6-, and 8-mm chords. Subjects were fitted with toric orthokeratology lenses following the manufacturer's guidelines based on elevation. Twenty subjects completed 10 days of wear. A masked examiner assessed movement and centration via slitlamp videos and quantified treatment zone and decentration from tangential power difference tomography maps. Correlations between variables were assessed. Results: Average corneal astigmatism was 2.20 +/- 0.70 DC and peripheral elevation was 50.88 +/- 18.92 mu m and they were strongly correlated (4 mm R-2=0.96, 6 mm R-2=0.92, 8 mm R-2=0.86, all P<0.001). Each diopter of astigmatism equated to 25 mu m of elevation at an 8-mm chord. Via slitlamp, average treatment zone area was 12.73 +/- 4.62 mm(2) and 13 lenses decentered. From tomography, average treatment zone area was 7.16 +/- 2.56 mm(2) and 17 were decentered. Tomography treatment zone area was negatively correlated with central corneal astigmatism (R-2=0.60) and elevation at an 8-mm chord (R-2=0.64, both P<0.001). Conclusions: For tomography images, central corneal astigmatism was highly correlated with peripheral elevation and may be a more expedient measure for clinical use. Treatment area decreased as corneal astigmatism and elevation increased.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据