4.7 Article

Vessel-selective 4D-MR angiography using super-selective pseudo-continuous arterial spin labeling may be a useful tool for assessing brain AVM hemodynamics

期刊

EUROPEAN RADIOLOGY
卷 30, 期 12, 页码 6452-6463

出版社

SPRINGER
DOI: 10.1007/s00330-020-07057-4

关键词

Magnetic resonance imaging; Magnetic resonance angiography; Arteriovenous malformations; Brain

资金

  1. JSPS KAKENHI [JP17K10410, JP20K08111]

向作者/读者索取更多资源

Objectives To evaluate the usefulness of 4D-MR angiography based on super-selective pseudo-continuous ASL combined with keyhole and view-sharing (4D-S-PACK) for vessel-selective visualization and to examine the ability of this technique to visualize brain arteriovenous malformations (AVMs). Methods In this retrospective study, 15 patients (ten men and five women, mean age 44.0 +/- 16.9 years) with brain AVMs were enrolled. All patients were imaged with 4D-PACK (non-selective), 4D-S-PACK, and digital subtraction angiography (DSA). Observers evaluated vessel selectivity, identification of feeding arteries and venous drainage patterns, visualization scores, and contrast-to-noise ratio (CNR) for each AVM component. Measurements were compared between the MR methods. Results Vessel selectivity was graded 4 in 43/45 (95.6%, observer 1) and 42/45 (93.3%, observer 2) territories and graded 3 in two (observer 1) and three (observer 2) territories. The sensitivity and specificity for identification of feeding arteries for both observers was 88.9% and 100% on 4D-PACK, and 100% and 100% on 4D-S-PACK, respectively. For venous drainage, the sensitivity and specificity was 100% on both methods for observer 1. The sensitivity and specificity for observer 2 was 94.4% and 83.3% on 4D-PACK, and 94.4% and 91.7% on 4D-S-PACK, respectively. The CNRs at the timepoint of 1600 ms were slightly lower in 4D-S-PACK than in 4D-PACK for all AVM components (Feeding artery,p = .02; nidus,p = .001; and draining artery,p = .02). The visualization scores for both observers were not significantly different between 4D-PACK and 4D-S-PACK for all components. Conclusions 4D-S-PACK could be a useful non-invasive clinical tool for assessing hemodynamics in brain AVMs.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据