Experimental and theoretical investigation on defrosting characteristics of a multi-split air source heat pump with vapor injection

期刊

ENERGY AND BUILDINGS
卷 217, 期 -, 页码 -

出版社

ELSEVIER SCIENCE SA
DOI: 10.1016/j.enbuild.2020.109938

关键词

Defrosting performance; Multi-split air source heat pump; Vapor injection; Scroll compressor; Injection pressure difference

资金

  1. National Natural Science Foundation of China [51878209]

向作者/读者索取更多资源

During the defrosting process of an air source heat pump with vapor injection (ASHPVI), the defrosting duration lasts rather long due to shortage of heat sources for defrost. In theory, vapor injection during defrosting can shorten defrosting duration due to the increase of discharge refrigerant and power input of compressor. However, the injection electronic expansion valve is always turned off during defrosting because vapor injection technology is mainly used for heating mode. To shorten the defrosting duration of ASHPVIs, a test rig using a multi-split air source heat pump with vapor injection was established. Its defrosting performance was investigated through experiment and theoretical analysis. Results showed that the injection ratio was 0-10.08% during defrosting experiment, which shortened the defrosting duration by 7.75%. The defrosting efficiency reached up to 54.11% at the outdoor temperature of -7.7 degrees C. In addition, the effect of vapor injection on defrosting speed was mainly at the evaporating melted frost stage. The results of preliminary experiments showed a little refrigerant could be injected into compressor at defrosting initial stage and melting frost stage, but the amount of vapor injection increased obviously and accelerated defrosting speed at evaporating melted frost stage owing to high injection pressure difference. (C) 2020 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据