4.5 Article

Amperometric Tyrosinase Biosensor Based on Carbon Black Paste Electrode for Sensitive Detection of Catechol in Environmental Samples

期刊

ELECTROANALYSIS
卷 33, 期 2, 页码 431-437

出版社

WILEY-V C H VERLAG GMBH
DOI: 10.1002/elan.202060084

关键词

tyrosinase enzyme; electrochemical biosensor; glutaraldehyde; carbon black; catechol

资金

  1. CNPq [465571/2014-0, 405546/2018-1]
  2. FAPESP [2020/01050-5, 2014/50945-4]
  3. PROJ. AUX/PE/PROEX CAPES [0674/2018]
  4. Fundacao de Amparo a Pesquisa do Estado de Sao Paulo (FAPESP) [14/50945-4] Funding Source: FAPESP

向作者/读者索取更多资源

A renewable tyrosinase-based biosensor for catechol detection was developed in this work, showing high accuracy and sensitivity in experiments, with successful application in river water samples. The biosensor is advantageous for its direct detection without the use of a mediator and its potential for immobilizing other enzymes and biomolecules with low-cost materials.
In this work, a renewable tyrosinase-based biosensor was developed for the detection of catechol, using a carbon black paste electrode, without any mediator. The effect of pH, type of electrolyte, and amount of tyrosinase enzyme were explored for optimum analytical performance. The best-performing biosensor in amperometric experiments at potential -0.2 Vvs. Ag/AgCl (3 mol L-1KCl) was obtained using a 0.1 mol L-1 phosphate buffer solution (pH 7.0) as electrolyte. Under optimized conditions, the proposed biosensor had two concentration linear ranges from 5.0x10(-9) to 4.8x10(-8) and from 4.8x10(-8) to 8.5x10(-6) mol L-1 and a limit of detection of 1.5x10(-9) mol L-1. The apparent Michaelis-Menten constant (KMMMapp) was calculated by the amperometric method, and the obtained value was 1.2x10(-5) mol L(-1)whose result was similar when compared with other studies previously. The biosensor was applied in river water samples, and the results were very satisfactory, with recoveries near 100 %. In addition, the response of this biosensor for different compounds, taking into account their molecular structures was investigated and the results obtained showed no interference with the response potential of catechol. The electrochemical biosensor developed in this work can be considered highly advantageous because it does not require the use of a mediator (direct detection) for electrochemical response, and also because it is based on a low-cost materials that can be used with success to immobilise other enzymes and/or biomolecules.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据