4.4 Review

Comparison of Second-Generation Basal Insulin Analogs: A Review of the Evidence from Continuous Glucose Monitoring

期刊

DIABETES TECHNOLOGY & THERAPEUTICS
卷 23, 期 1, 页码 20-30

出版社

MARY ANN LIEBERT, INC
DOI: 10.1089/dia.2020.0180

关键词

Continuous glucose monitoring; Basal insulins; Insulin therapy; Time in Range

资金

  1. Sanofi

向作者/读者索取更多资源

The review of current CGM evidence for second-generation basal insulins in both people with type 1 and type 2 diabetes highlights the complexity of evaluating basal insulins with various CGM-related metrics. The identified studies had small sample sizes, short durations, and lacked statistically significant between-treatment differences. There is a need for further studies on second-generation basal insulin analogs considering standard metrics proposed by the TIR consensus group, with attention to sample size and study duration.
Many people with insulin-treated diabetes continue to experience inadequate glycemic control and a high incidence of hypoglycemic events, despite improvements in therapeutic strategies. While glycated hemoglobin (HbA(1c)) is currently recognized as the gold-standard for assessing glycemic control, the measure reflects mean blood glucose levels over a period of time, does not inform on acute glycemic deviations, and can be unreliable in certain populations. Continuous glucose monitoring (CGM) facilitates the acquisition of blood glucose data around the clock and, importantly, predicts and/or captures acute hyper- and hypoglycemic episodes. In light of the recent publication of the Time in Range (TIR) International Consensus Group report on key CGM metrics, we performed a review of current CGM evidence for second-generation basal insulins in both people with type 1 and type 2 diabetes. The identified studies highlight the varied CGM-related metrics used to assess basal insulins, which complicate comparisons. Furthermore, all studies had small sample sizes and typically were of short duration, which may account for the lack of statistically significant between-treatment differences observed. Differences were seen in the titration approaches used and the settings in which participants were observed. These results highlight the need for further studies of second-generation basal insulin analogs that are designed to capture the standard metrics proposed by the TIR consensus group, with additional consideration given to sample size and study duration.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据