Evaluation of serum electrolytes measurement through the 6-year trueness verification program in China

期刊

CLINICAL CHEMISTRY AND LABORATORY MEDICINE
卷 59, 期 1, 页码 107-116

出版社

WALTER DE GRUYTER GMBH
DOI: 10.1515/cclm-2020-0355

关键词

electrolytes; reference methods; standardization; trueness verification

资金

  1. National Key Technology R&D Program of China [2011AA02A102]

向作者/读者索取更多资源

The ETV program in China has shown that using commutable materials assigned via reference methods can improve accuracy and reproducibility in laboratory measurements, with homogeneous systems performing better in calcium and magnesium measurements. Variations in bias were observed among different instruments for sodium, potassium, calcium, and magnesium measurements.
Objectives: The National Center for Clinical Laboratories (NCCL) in China initiated a serum electrolyte trueness verification (ETV) program in 2014 for measurement standardization. Methods: Every year, two levels of fresh frozen commutable serum samples determined by inductively coupled plasma mass spectrometry (ICP-MS) reference methods were transported to participating clinical laboratories for the measurement of sodium, potassium, calcium and magnesium. Both samples were measured 15 times in 3 days, and the mean values and coefficient variations (CVs) were calculated from the results. The tolerance limits of trueness (bias), precision (CV) and accuracy (TE) based on the biological variation database were used as the evaluation criteria. The overall trend of the ETV program over 6 years was surveyed by calculating the pass rates of the participating laboratories. The mean bias, inter-laboratory CV, and TE of all laboratory results were analysed. Furthermore, homogeneous and heterogeneous systems were compared, and the bias and CV results of mainstream analysis systems were analysed. Results: Pass rates of the three quality specifications increased, and the overall mean bias and inter-laboratory CVs decreased. The homogeneous system was superior to the heterogeneous system for calcium and magnesium measurements. For sodium, potassium, calcium and magnesium, the minimum bias corresponded to Hitachi, Siemens, Beckman AU and Roche, respectively. For interlaboratory robust CVs, no obvious differences were observed between each peer group. Conclusions: The commutable ETV materials assigned via reference methods can evaluate the accuracy and reproducibility of an individual laboratory and the calibration traceability and uniformity between laboratories for measurements.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据