Diffusion coefficients of polar organic compounds in agarose hydrogel and water and their use for estimating uptake in passive samplers

期刊

CHEMOSPHERE
卷 249, 期 -, 页码 -

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.chemosphere.2020.126183

关键词

Diffusion coefficient; Passive sampling; DGT; Polar organic compounds; Agarose hydrogel; Taylor dispersion

资金

  1. Ministry of Education, Youth and Sports, Czech Republic [LM2018121, 7AMB16DE004]
  2. European Structural and Investment Funds, Operational Programme Research, Development, Education [CZ.02.1.01/0.0/0.0/16_013/0001761]
  3. German Academic Exchange Service, Germany (DAAD) [57219068]

向作者/读者索取更多资源

Diffusion coefficient (D) is an important parameter for prediction of micropollutant uptake kinetics in passive samplers. Passive samplers are nowadays commonly used for monitoring trace organic pollutants in different environmental matrices. Samplers utilising a hydrogel layer to control compound diffusion are gaining popularity. In this work we investigated diffusion of several perfluoroalkyl substances, currently used pesticides, pharmaceuticals and personal care products in 1.5% agarose hydrogel by measuring diffusion coefficients using two methods: a diffusion cell and a sheet stacking technique. Further, diffusion coefficients in water were measured using Taylor dispersion method. The sheet stacking method was used to measure D at 5, 12, 24, and 33 degrees C in order to investigate temperature effect on diffusion. Median D values ranged from 2.0 to 8.6 x 10(-6) cm(2) s(-1) and from 2.1 to 8.5 x 10(-6) cm(2) s(-1) for the diffusion cell and sheet stack methods respectively. For most compounds, the variability between replicates was higher than the difference between values obtained by the two methods. Rising temperature from 10 to 20 degrees C increases the diffusion rate by the factor of 1.41 +/- 0.10 in average. In water, average D values ranged from 3.03 to 10.0 x 10(-6) cm(2) s(-1) and were comparable to values in hydrogel, but some compounds including perfluoroalkyl substances with a long aliphatic chain could not be evaluated properly due to sorptive interactions with capillary walls in the Taylor dispersion method. Sampling rates estimated using the measured D values were systematically higher than values estimated from laboratory sampler calibration in our previously published study, by the factor of 2.2 +/- 1.0 in average. (C) 2020 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据