4.5 Article

Concurrent validity and reliability of measuring range of motion during the cervical flexion rotation test with a novel digital goniometer

期刊

BMC MUSCULOSKELETAL DISORDERS
卷 21, 期 1, 页码 -

出版社

BMC
DOI: 10.1186/s12891-020-03525-6

关键词

Reliability; Validity; Intra-rater; Inter-rater; Flexion-rotation-test; Neck pain; Headache; Cervical; Zebris; Goniometer

向作者/读者索取更多资源

Background: Headache is a common and costly health problem. Although the pathogenesis of headache is heterogeneous, reported contributing factors are dysfunctions of the upper cervical spine. The flexion rotation test (FRT) is a commonly used diagnostic test to detect upper cervical movement impairment. A digital goniometer may support precise measurement of movement impairment in the upper cervical spine. However, its reliability and validity is not assessed, yet. The aim of this study was to investigate the reliability and validity of the digital goniometer compared to an ultrasound-based movement analysis system. Methods: Two separate cross-sectional studies were conducted using the digital goniometer EasyAngle (Meloq AB, Stockholm, Sweden) for a) investigating the concurrent validity of upper cervical range of motion (ROM) during the FRT and b) determining the inter- and intra-rater reliability in the target population of patients with head and neck pain. Sixty-two participants, 39 with and 23 without head and neck pain, were recruited for the concurrent validity study. For the reliability study, a total of 50 participants were recruited. Intraclass correlation coefficients (ICC) and Bland Altmann plots were used to assess validity and ICC values, Bland Altmann plots as well as Kappa coefficients were used for estimating intra-rater and inter-rater reliability. Results: Concurrent validity was strong with an ICC (2,1) of 0.97 for ROM to either side (95%CI = 0.95-0.98). Bland Altman Plots revealed a mean difference between measurement systems of 0.5 degrees for the left and 0.11 degrees for the right side. The inter-rater ICC (2,1) was 0.66 (95%CI 0.47-0.79,p < 0.001, SEM 6.6 degrees), indicating good reliability. The limits of agreement were between 10.25 degrees and - 11.89 degrees, the mean difference between both raters was - 0.82 degrees. Intra-rater reliability for the measurement of ROM during the FRT was between 0.96 (ICC 3,1) for rater 1 and 0.94 (ICC 3,1) for rater 2. Conclusions The digital goniometer demonstrated strong concurrent validity and good to strong reliability and can be used in clinical practice to accurately determine movement impairment in the upper cervical spine.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据