4.7 Article

Development and evaluation of a robust temperature sensitive algorithm for long term NO2 gas sensor network data correction

期刊

ATMOSPHERIC ENVIRONMENT
卷 230, 期 -, 页码 -

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.atmosenv.2020.117509

关键词

Sensor network; Robustness analysis; Sensor calibration

资金

  1. Science and Technology Commission of Shanghai Municipality [17DZ1203101, 17DZ1203105]
  2. Research Grants Council of the Hong Kong SAR [C7064-18G-2, E-HKUST601/19]
  3. Special Fund Project for Science and Technology Innovation Strategy of Guangdong Province [2019B121205004]

向作者/读者索取更多资源

Low-cost sensors (LCS) for air-quality monitoring have shown huge potential in enhancing spatial and temporal resolutions at a lower cost, greater flexibility in use and with less maintenance than fixed-air quality monitoring stations (AQMS). There are numerous reports showing sensor-based systems perform well under laboratory conditions. However, the accuracy of LCS operated under field conditions has been reported to deviate from their use in these controlled environments. Previous studies have employed various mathematical techniques to improve system performance. These include classic multivariate regression model (MLR) to incorporate ambient factors (e.g. temperature & relative humidity) and machine learning (ML) models for integrating complex nonlinear sensor responses for gaseous pollutant concentration predictions. However, routine field calibrations may cause data inconsistency during measurement periods. This study first illustrates the limitations of short-term routine calibration by comparing performances of existing MLR and ML models. Further, based on a long-term evaluation period, a newly principle-based method named Temperature Look-Up (TLU) model was built and compared with the existing MLR and ML models. Measurements were taken for 8 months (August 2017 to March 2018) in SanMenXia (SMX) city, China, using 8 sets of sensor systems (Mini Air Stations, MAS). One MAS was co-located with AQMS to provide data to assess the principle, whereas the other 7 MAS were used for verification. The TLU model showed the best performance for long term validation (4 months) and high model inner coherence (R-2 > 0.91). Meanwhile, the TLU model also shows the fast convergence (40 days) to reach stable prediction performance, and spatial representativeness in the sensor network. Recommendations on sensor network deployment and strategy for data maintenance based on our observations are discussed.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据