4.3 Article

Outcomes of Open Versus Percutaneous Access for Patients Enrolled in the GREAT Registry

期刊

ANNALS OF VASCULAR SURGERY
卷 70, 期 -, 页码 370-377

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.avsg.2020.06.033

关键词

-

向作者/读者索取更多资源

This study analyzed data from the GREAT registry and found that patients undergoing EVAR and TEVAR with percutaneous access had lower complication rates and shorter length of stay compared to those with open or combined access techniques. The study also revealed that there was no significant difference in complication rates between percutaneous and cutdown access techniques, and that longer length of stay was associated with higher rates of access site complications.
Background: Arterial access and device delivery in endovascular aortic repair (EVAR) and thoracic endovascular aortic repair (TEVAR) have evolved from open femoral or iliac artery exposure to selective percutaneous arterial access. Although regional application of percutaneous access for these 2 procedures varies widely, the use of this technique continues to increase. Currently, differences in the use of percutaneous access between EVAR and TEVAR have not been well explored. The Gore Global Registry for Endovascular Aortic Treatment (GREAT) registry collected relevant data for evaluation of these issues and the comparative results between open and percutaneous approaches in regard to complication rates and length of stay (LOS). Methods: This study was performed via a retrospective review of patients from the GREAT registry (Clinicaltrials.gov no. NCT01658787). The primary variable of this study was access site complications including postoperative hematoma, vessel dissection, and pseudoaneurysm. Patients were categorized by abdominal (EVAR) and thoracic (TEVAR) aortic procedures using percutaneous-only, cutdown-only, and combined vascular access techniques for a total of 6 groups. Standard statistical methodology was used to perform single-variable and multivariable analysis of a variety of covariates including LOS, geographical location of procedure, procedural success rate, and access sheath size. Results: Of 4,781 patients from the GREAT registry, 3,837 (80.3%) underwent EVAR and 944 (19.7%) underwent TEVAR with percutaneous-only access techniques being used in 2,017 (42.2%) and cutdown-only in 2,446 (51.2%). There was variable application of percutaneous access by geographic region with Australia and New Zealand using this technique more frequently and Brazil using percutaneous access the least. No significant difference in the rate of access site complications was detected between the 6 groups of patients in the study; however, significantly lower rates of access site complications were associated with percutaneous-only compared with both cutdown-only and combined techniques (P = 0.03). In addition, associated with significantly higher rates of access site complications was longer LOS (P < 0.01). Average LOS was 5.2 days and was higher in the TEVAR group (10.1 days) than that in EVAR (4.0 days, P < 0.05). Increased sheath size does not appear to increase the risk of access site complication. Conclusions: There was no significant difference found in the complication rate between percutaneous and cutdown access techniques. This analysis demonstrates that percutaneous-only access is safe, has low complication rates, and has lower LOS compared with open access or combined access techniques.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据