4.6 Article

Body Habitus and Dynamic Surgical Conditions Independently Impair Pulmonary Mechanics during Robotic-assisted Laparoscopic Surgery A Cross-sectional Study

期刊

ANESTHESIOLOGY
卷 133, 期 4, 页码 750-763

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/ALN.0000000000003442

关键词

-

资金

  1. Foundation for Anesthesia Education and Research Medical Student Anesthesia Research Fellowship

向作者/读者索取更多资源

Background: Body habitus, pneumoperitoneum, and Trendelenburg positioning may each independently impair lung mechanics during robotic laparoscopic surgery. This study hypothesized that increasing body mass index is associated with more mechanical strain and alveolar collapse, and these impairments are exacerbated by pneumoperitoneum and Trendelenburg positioning. Methods: This cross-sectional study measured respiratory flow, airway pressures, and esophageal pressures in 91 subjects with body mass index ranging from 18.3 to 60.6 kg/m(2). Pulmonary mechanics were quantified at four stages: (1) supine and level after intubation, (2) with pneumoperitoneum, (3) in Trendelenburg docked with the surgical robot, and (4) level without pneumoperitoneum. Subjects were stratified into five body mass index categories (less than 25, 25 to 29.9, 30 to 34.9, 35 to 39.9, and 40 or higher), and respiratory mechanics were compared over surgical stages using generalized estimating equations. The optimal positive end-expiratory pressure settings needed to achieve positive end-expiratory transpulmonary pressures were calculated. Results: At baseline, transpulmonary driving pressures increased in each body mass index category (1.9 +/- 0.5 cm H2O; mean difference +/- SD;P< 0.006), and subjects with a body mass index of 40 or higher had decreased mean end-expiratory transpulmonary pressures compared with those with body mass index of less than 25 (-7.5 +/- 6.3vs.-1.3 +/- 3.4 cm H2O;P< 0.001). Pneumoperitoneum and Trendelenburg each further elevated transpulmonary driving pressures (2.8 +/- 0.7 and 4.7 +/- 1.0 cm H2O, respectively;P< 0.001) and depressed end-expiratory transpulmonary pressures (-3.4 +/- 1.3 and -4.5 +/- 1.5 cm H2O, respectively;P< 0.001) compared with baseline. Optimal positive end-expiratory pressure was greater than set positive end-expiratory pressure in 79% of subjects at baseline, 88% with pneumoperitoneum, 95% in Trendelenburg, and ranged from 0 to 36.6 cm H2O depending on body mass index and surgical stage. Conclusions: Increasing body mass index induces significant alterations in lung mechanics during robotic laparoscopic surgery, but there is a wide range in the degree of impairment. Positive end-expiratory pressure settings may need individualization based on body mass index and surgical conditions.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据