期刊
ANALYTICAL SCIENCES
卷 36, 期 6, 页码 709-715出版社
JAPAN SOC ANALYTICAL CHEMISTRY
DOI: 10.2116/analsci.19P413
关键词
Metal ion; medicinal drug; metal complex formation; solid phase extraction; high-performance liquid chromatography
A high-throughput screening method for the complexation between metal ions and drugs was established by combining solid-phase extraction (SPE) using a nitrilotriacetic acid (NTA) modified silica spin cartridge with subsequent HPLC analysis. First, a test metal ion solution was passed through the NTA cartridge, then a test drug solution diluted in phosphate buffered saline (pH 7.4) was passed through the metal-chelated NTA cartridge. The complexation behavior between the metal and the drug on the NTA cartridge was evaluated by HPLC quantification of the drug in the SPE eluate. Comprehensive analysis of the complexation behavior between 11 different metal ions and 55 drugs showed that Cu2+, Ni2+, Co2+, Zn2+, Cr3+ and Fe3+ formed complexes with 12, 5, 4, 2, 1 and 1 kinds of drugs, respectively. Bromazepam selectively formed complexes with Cu2+, Ni2+ and Co2+.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐