4.3 Article

Optimization of [18F]PSMA-1007 PET-CT using regularized reconstruction in patients with prostate cancer

期刊

EJNMMI PHYSICS
卷 7, 期 1, 页码 -

出版社

SPRINGER
DOI: 10.1186/s40658-020-00298-8

关键词

PET-CT; PSMA; Block-sequential regularized expectation maximization; Q; Clear; Image quality; [18F]PSMA-1007

资金

  1. Knut and Alice Wallenberg foundation
  2. Medical Faculty at Lund University
  3. Swedish Prostate Cancer foundation
  4. Region Skane

向作者/读者索取更多资源

Background Prostate-specific membrane antigen (PSMA) radiotracers such as [F-18]PSMA-1007 used with positron emission tomography-computed tomography (PET-CT) is promising for initial staging and detection of recurrent disease in prostate cancer patients. The block-sequential regularization expectation maximization algorithm (BSREM) is a new PET reconstruction algorithm, which provides higher image contrast while also reducing noise. The aim of the present study was to evaluate the influence of different acquisition times and different noise-suppressing factors in BSREM (beta values) in [F-18]PSMA-1007 PET-CT regarding quantitative data as well as a visual image quality assessment. We included 35 patients referred for clinical [F-18]PSMA-1007 PET-CT. Four megabecquerels per kilogramme were administered and imaging was performed after 120 min. Eighty-four image series per patient were created with combinations of acquisition times of 1-4 min/bed position and beta values of 300-1400. The noise level in normal tissue and the contrast-to-noise ratio (CNR) of pathological uptakes versus the local background were calculated. Image quality was assessed by experienced nuclear medicine physicians. Results The noise level in the liver, spleen, and muscle was higher for low beta values and low acquisition times (written as activity time products (ATs = administered activity x acquisition time)) and was minimized at maximum AT (16 MBq/kg min) and maximum beta (1400). There was only a small decrease above AT 10. The median CNR increased slowly with AT from approximately 6 to 12 and was substantially lower at AT 4 and higher at AT 14-16. At AT 4-6, many images were regarded as being of unacceptable quality. For AT 8, beta values of 700-900 were considered of acceptable quality. Conclusions An AT of 8 (for example as in our study, 4 MB/kg with an acquisition time of 2 min) with a beta value of 700 performs well regarding noise level, CNR, and visual image quality assessment.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据