Influence of ageing on oil degradation and gassing tendency under high-energy electrical discharge faults for mineral oil and synthetic ester

期刊

HIGH VOLTAGE
卷 5, 期 6, 页码 731-738

出版社

INST ENGINEERING TECHNOLOGY-IET
DOI: 10.1049/hve.2019.0291

关键词

electric breakdown; ageing; discharges (electric); insulating oils; oil degradation; high-energy electrical discharge faults; mineral oil; synthetic ester; fresh oils; aged oils; fault gas analysis; ultraviolet spectroscopy; ASTM standard test methods; Duval's triangle methods; Duval's pentagon methods

向作者/读者索取更多资源

In this work, mineral oil and synthetic esters were selected at different ageing factors (based on acidity values). Fresh and aged oils have been subjected to high-energy discharges (repeated 100 breakdowns) to simulate electric faults of highly vulnerable intensity. The intent of this work is to understand the influence of high-energy electric faults on oil degradation and gassing tendency at different ageing conditions. In this study, the influence of the high-energy discharges on degradation and gassing tendency at different ageing factors is reported for mineral oil and synthetic esters. Oil degradation is reported by adopting ultraviolet spectroscopy, turbidity and particle counter as per american society for testing and materials (ASTM) standard test methods. Gassing tendencies and fault gas analysis are understood by dissolved the gas analysis using Duval's triangle and Duval's pentagon methods for mineral and non-mineral oils. It is found that the influence of high-energy discharges on oil degradation is higher in mineral oils to that of the synthetic esters. The intensity of the gassing tendency is higher for ester fluids; however, as per the Duval methods, the faulty conditions are at lower levels as compared to mineral oils.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据