4.7 Article

Raman and infrared spectroscopic quantification of the carbonate concentration in K2CO3 aqueous solutions with water as an internal standard

期刊

GEOSCIENCE FRONTIERS
卷 12, 期 2, 页码 1018-1030

出版社

CHINA UNIV GEOSCIENCES, BEIJING
DOI: 10.1016/j.gsf.2020.03.002

关键词

Carbonate aqueous solution; Micro fluid inclusion; K2CO3 concentration; Relative Raman intensity; Relative IR absorbance

资金

  1. DREAM project of MOST, China [2016YFC0600408]
  2. Strategic Priority Research Program (B) of Chinese Academy of Sciences [XDB18000000]
  3. Program of the National Mineral Rock and Fossil Specimens Resource Center from MOST, China

向作者/读者索取更多资源

Carbonate-bearing fluids are commonly found in various geological settings and are crucial in transporting elements like rare earth elements. Spectroscopic methods such as Raman spectroscopy and infrared spectroscopy show promise in quantifying carbonate concentrations in fluid inclusions, despite technical challenges. Calibration experiments using Raman and infrared spectra can potentially provide accurate quantification of carbonate concentrations and reveal the influence of K2CO3 concentration on the physical and chemical properties of the fluids.
Carbonate-bearing fluids widely exist in different geological settings, and play important roles in transporting some elements such as the rare earth elements. They may be trapped as large or small fluid inclusions (with the size down to <1 mu m sometimes), and record critical physical-chemical signals for the formations of their host minerals. Spectroscopic methods like Raman spectroscopy and infrared spectroscopy have been proposed as effective methods to quantify the carbonate concentrations of these fluid inclusions. Although they have some great technical advantages over the conventional microthermometry method, there are still some technical difficulties to overcome before they can be routinely used to solve relevant geological problems. The typical limitations include their interlaboratory difference and poor performance on micro fluid inclusions. This study prepared standard ion-distilled water and K2CO3 aqueous solutions at different molarities (from 0.5 to 5.5 mol/L), measured densities, collected Raman and infrared spectra, and explored correlations between the K2CO3 molarity and the spectroscopic features at ambient P-T conditions. The result confirms that the Raman O-H stretching mode can be used as an internal standard to determine the carbonate concentrations despite some significant differences among the correlations, established in different laboratories, between the relative Raman intensity of the C-O symmetric stretching mode and that of the O-H stretching mode. It further reveals that the interlaboratory difference can be readily removed by performing one high-quality calibration experiment, provided that later quantifying analyses are conducted using the same Raman spectrometer with the same analytical conditions. Our infrared absorption data were collected from thin fluid films (thickness less than similar to 2 mu m) formed by pressing the prepared solutions in a Microcompression Cell with two diamond-II plates. The data show that both the O-H stretching mode and the O-H bending mode can be used as internal standards to determine the carbonate concentrations. Since the IR signals of the C-O antisymmetric stretching vibration of the CO32- ion, and the O-H stretching and bending vibrations from our thin films are very strong, their relative IR absorbance intensity, if well calibrated, can be used to investigate the micron-sized carbonate-bearing aqueous fluid inclusions. This study establishes the first calibration of this kind, which may have some applications. Additionally, our spectroscopic data suggest that as the K2CO3 concentration increases the aqueous solution forms more large water molecule clusters via more intense hydrogen-bonding. This process may significantly alter the physical and chemical behavior of the fluids.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据