4.7 Article

In-situ lubricating oil condition sensoring method based on two-channel and differential dielectric spectroscopy combined with supervised hierarchical clustering analysis

期刊

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.chemolab.2016.09.004

关键词

Engine lubricating oil; Two-channel and differential dielectric spectroscopy (TD-DES); Hierarchical clustering analysis (HCA); Fourier transform infrared spectroscopy (FT-IR)

资金

  1. National Natural Science Foundation of China [21205136]
  2. Chongqing Science & Technology Commission frontier and applied basic research project (general) of China [cstc2014jcyjA50007]
  3. Chongqing graduate research & innovation project of China [CYB14101]

向作者/读者索取更多资源

In this article, the two-channel and differential dielectric spectroscopy (TD-DES) has been proposed and employed to obtain the dielectric submicroscopic phase (DSP) and heterogeneous characteristics of the lubricating oil system compared with the Fourier transform infrared spectroscopy (FT-IR) data. The hierarchical clustering analysis (HCA) results based on TD-DES data were well consistent with those based on the FT-IR data. The two phases including the DSP and heterogeneous characteristics of the lubricating oil system featured by TD-DES were the special with regard to the function-group characteristics expressed by FT-IR data, which proved that the TD-DES method was more effective and sensitive than FT-IR to monitor the lubricant systems condition during the early oxidation degradation. A new and qualitative oil condition monitoring technique based on TD-DES and supervised hierarchical clustering analysis (S-HCA) has been proposed, by means of which the in-service lubricating oil samples can be classified well-separately into six clusters: (1) the fresh stage (cluster F), (2) the initial oxidation stage (cluster A), (3) the moderate oxidation stage (cluster B), (4) the accelerated oxidation stage (cluster C), (5) the strong oxidation stage (cluster D), (6) the heterogeneous system stage (cluster E). The signal for an oil change need should be sent in the stage (5) and the lubricating oils in stage (6) could damage the engine. By the leave-one-out cross-validation (LOO CV), the 33 in-service lubricant samples were all clustered correctly, which proved that the TD-DES analysis method combined with S-HCA can provide significant oil change advice. (C) 2016 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据