4.7 Article

Resolving the thickness of peat deposits with contact-less electromagnetic methods: A case study in the Venice coastland

期刊

SCIENCE OF THE TOTAL ENVIRONMENT
卷 737, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.scitotenv.2020.139361

关键词

Peatland volume; Peat thickness; Contact-less geophysical methods; FDEM; Airborne electromagnetics

资金

  1. European Union [747809]
  2. University of Padova
  3. Italian Ministry of Education, University and Research within the National Research Program
  4. Marie Curie Actions (MSCA) [747809] Funding Source: Marie Curie Actions (MSCA)

向作者/读者索取更多资源

Peat soils are typical deposits characterizing wetlands and reclaimed farmlands. They are important carbon reservoirs and when degraded (e.g., erosive processes, fires, draining and plowing) massive carbon dioxide volumes are released. This leads to increase greenhouse effect and induce serious land subsidence. Thus, mapping the volume of peat deposits is crucial in order to estimate the carbon mass and the potential release of carbon dioxide and consequent loss in soil elevation. Despite the importance of such estimations, forecasting and quantifying the peat thickness is still a challenge. Direct sediment coring provides local information that is difficult to extend to large territories. Indirect geophysical methods are unable to resolve lithological contrasts in the presence of saltwater contamination in coastal areas. In this work, we show the results obtained using two contact-less electromagnetic methods for the characterization of peat deposits in a peatland site of the Venice coastland, Italy. Specifically, a multi-frequency portable instrument (FDEM) and an airborne time-domain electromagnetic one (AEM), known for their very high and relatively low vertical resolution respectively, were used to collect data over a former wetland then reclaimed for agricultural purposes. Additional electrical resistivity tomography (ERT) data are used together with sediment core data to assess the effectiveness and accuracy of the contactless methods. Results show that both FDEM and AEM are very effective in detecting the presence of the peat layer, despite its low thickness (<2 m) and the high electro-conductive subsoil because of saltwater contamination. However, the AEM method overestimated the peat thickness while the FDEM could accurately resolve the peat thickness even where the layer was thinner than 1 m. When compared to the electrical features extracted from the ERT, discrepancies are on average lower than 30%; when compared to the borehole data, discrepancies are on average slightly higher than 6%. (c) 2020 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据