Dosimetric characteristics of the INTRABEAM ® system with spherical applicators in the presence of air gaps and tissue heterogeneities

期刊

RADIATION AND ENVIRONMENTAL BIOPHYSICS
卷 59, 期 2, 页码 295-306

出版社

SPRINGER
DOI: 10.1007/s00411-020-00835-0

关键词

IORT; Spherical applicator; Air gap; Tissue heterogeneities; Monte carlo simulation

资金

  1. Radiation Oncology Research Center, Tehran University of Medical Sciences and Health Services [98-01-207-38809]

向作者/读者索取更多资源

The main aim of this study was to investigate the dosimetric characteristics of the INTRABEAM (R) system in the presence of air gaps between the surface of applicators (APs) and tumor bed. Additionally, the effect of tissue heterogeneities was another focus. Investigating the dosimetric characteristics of the INTRABEAM (R) system is essential to deliver the required dose to the tumor bed correctly and reduce the delivered dose to the ribs and lung. Choosing the correct AP size and fitting it to the lumpectomy cavity is essential to remove the effect of air gaps and avoid inaccurate dose delivery. Consequently, the Geant4 toolkit was used to simulate the INTRABEAM (R) system with spherical APs of various sizes. The wall effect of the ion chamber (IC) PTW 34013 used in the present study was checked. The simulations were validated in comparison with measurements, and then used to calculate any inaccuracies in dose delivery in the presence of 4- and 10-mm air gaps between the surface of the APs and the tumor bed. Also, the doses received due to tissue heterogeneities were characterized. It turned out that measurements and simulations were approximately in agreement (+/- 2%) for all sizes of APs. The perturbation factor introduced by the IC due to differences in graphite-coated polyethylene and air as compared to the phantom material was approximately equal to one for all AP. The greatest relative dose delivery difference was observed for an AP with a diameter of 1.5 cm, i.e., 44% and 70% in the presence of 4- and 10-mm air gaps, respectively. In contrast, the lowest relative dose delivery difference was observed for an AP with a diameter of 5 cm, i.e., 24% and 42% in the presence of 4- and 10-mm air gaps, respectively. Increasing APs size showed a decrease in relative dose delivery difference due to the presence of air gaps. In addition, the undesired dose received by the ribs turned out to be higher when a treatment site closer to the ribs was assumed. The undesired dose received by the ribs increased as the AP size increased. The lung dose turned out to be decreased due to the shielding effect of the ribs, small lung density, and long separation distance from the AP surface.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.2
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据