期刊
OPTICS LETTERS
卷 45, 期 14, 页码 3889-3892出版社
OPTICAL SOC AMER
DOI: 10.1364/OL.392088
关键词
-
类别
资金
- European Commission Marie Curie [708068]
- Deutsche Forschungsgemeinschaft [AB 668/1-1]
We synthesized and characterized ScVO4:Bi3+ thermographic phosphor particles and demonstrated their use as a tracer for temperature imaging in a near-ambient temperature liquid flow using a single laser/camera luminescence lifetime dual-frame ratio-based method. Owing to a high temperature sensitivity of up to 6%/degrees C, the single-shot single-pixel temperature precision at a 400 mu m spatial resolution is better than +/- 0.4 degrees C (1 sigma) across the 20 to 60 degrees C range, representing a factor >5 improvement compared to previous works using thermographic phosphors. The measurement duration is on the order of the luminescence lifetime (2 mu s), which is applicable in both gas and liquid flows. This is a general temperature imaging method for sensitive measurements in dynamic fluid mechanics and thermal science applications. (C) 2020 Optical Society of America
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐
暂无数据