- Directorate for Computer and Information Science and Engineering [IIS-1637961, IIS-1763689]
The state-of-art three-dimensional (3D) shape measurement with digital fringe projection (DFP) techniques assume that the influence of projector pixel shape is negligible. However, our research reveals that when the camera pixel size is much smaller than the projector pixel size in object space (e.g., 1/5), the shape of projector pixel can play a critical role on ultimate measurement quality. This paper evaluates the performance of two shapes of projector pixels: rectangular and diamond shaped. Both simulation and experimental results demonstrated that when the camera pixel size is significantly smaller than the projector pixel size, it is advantageous for ultrahigh resolution 3D shape measurement system to use a projector with rectangular-shaped pixels than a projector with diamond-shaped pixels. (C) 2020 Optical Society of America under the terms of the OSA Open Access Publishing Agreement
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐