4.7 Article

Absolute isotopic abundance ratios and the accuracy of Δ47 measurements

期刊

CHEMICAL GEOLOGY
卷 442, 期 -, 页码 83-96

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.chemgeo.2016.08.014

关键词

Clumped isotopes; Triple oxygen isotopes; Oxygen-17 anomalies; Absolute isotopic abundance ratios

资金

  1. Region Ile-de-France
  2. Direction des Sciences de la Matiere du Commissariat a l'Energie Atomique
  3. Institut National des Sciences de l'Univers, Centre National de la Recherche Scientifique
  4. Universtite de Versailles/Saint-Quentin-en-Yvelines

向作者/读者索取更多资源

Clumped isotope measurements aim to quantify some statistical properties of the isotopologue population in a given sample, which requires prior knowledge of the absolute isotopic abundance ratios in reference materials such as VSMOW or VPDB. In the case of CO2, matters are further complicated by the need to define a mass-dependent fractionation law linking the three stable isotopes of oxygen. Conversion from raw mass spectrometric data to mass-47 anomalies (Delta(47)) thus relies on four external parameters: the (C-13/C-12) ratio of VPDB, the (O-17/O-16) and (O-18/O-16) ratios of VSMOW (or VPDB-CO2), and the slope of the triple oxygen isotope line (lambda). Here we investigate the influence that these isotopic parameters exert on measured Delta(47) values, using (a) real-world data corresponding to seven months of measurements; (b) simple simulations based on randomly generated data; (c) precise comparisons between water-equilibrated CO2 samples and between carbonate standards believed to share quasi-identical Delta(47) values; and (d) reprocessing of two carbonate calibration data sets with different slopes of Delta(47) versus T. We demonstrate that the use of different sets of isotopic parameters generally produces systematic offsets as large as 0.04% in measured Delta(47) values, even after following the established standardization procedures. What's more, even using a single set of isotopic parameters can produce intra-and inter-laboratory discrepancies in measured Delta(47) values, if some of these parameters are inaccurate, and depending on the isotopic compositions of the standards used for conversion to the absolute scale of Dennis et al. (2011), these errors should correlate strongly with either delta C-13 or delta O-18, or more weakly with both. Based on measurements of samples expected to display quasi-identical Delta(47) values, such as 25 degrees C water-equilibrated CO2 with different carbon and oxygen isotope compositions, or high-temperature standards ETH-1 and ETH-2, we conclude that the traditional set of isotopic parameters used in all early clumped isotope studies produces large, systematic errors controlled by the relative bulk isotopic compositions of samples and standards. These errors are likely to be one of the key factors responsible for current inter-laboratory discrepancies, but cannot easily explain the conflicting carbonate calibration slopes obtained by different groups. By contrast, the isotopic parameters of Brand et al. (2010) appear to yield accurate Delta(47) values regardless of bulk isotopic composition. Based on these findings, we offer recommendations aiming to minimize errors related to the choice of isotopic parameters. (C) 2016 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据