4.5 Review

Comparative diagnostic efficacy of serum Krebs von den Lungen-6 and surfactant D for connective tissue disease-associated interstitial lung diseases A meta-analysis

期刊

MEDICINE
卷 99, 期 16, 页码 -

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/MD.0000000000019695

关键词

Bayesian analysis; connective tissue disease; diagnosis; interstitial lung disease; Krebs von den Lungen-6; surfactant protein D

资金

  1. Chinese National Key Technology R&D Program of Ministry of Science and Technology [2017YFC0907604]
  2. National Science and Technology Major Project of the Ministry of Science and Technology of China [2019ZX09734001-002-004]
  3. Medical and health science and technology innovation project of Chinese Academy of Medical Sciences [2019-I2M-2-008]
  4. National Natural Science Foundation of China [81601430, 81471615]

向作者/读者索取更多资源

Purpose: The aim of the study was to estimate and compare the diagnostic accuracy of serum Krebs von den Lungen-6 (KL-6) and surfactant protein D (SP-D) for identifying interstitial lung disease (ILD) from non-ILD among connective tissue disease (CTD) patients. Materials and Methods: Original articles on the diagnostic accuracy of serum KL-6 and SP-D in differentiating CTD-ILD from CTD-nonILD were identified from three public databases. The overall quality of evidence and methodologic quality of each eligible study were assessed by the Grading of Recommendations, Assessment, Development and Evaluation approach and Quality Assessment of Diagnostic Accuracy Studies, respectively. We used the bivariate model to calculate random-effect sensitivity, specificity, likelihood ratios, and area under curve. Furthermore, trial sequential analysis (TSA) was used to determine whether sample sizes incorporated in the meta-analysis were powerful for evaluating the diagnostic utility. Bayesian network analysis was performed to compare the diagnostic accuracy of 2 serum biomarkers in differentiating ILD among CTD patients and various subgroups. Results: Twenty-nine studies were included in the quantitative synthesis. No threshold effects were observed (allPvalues >.05). For diagnosis of ILD among CTD patients, overall sensitivity and specificity of serum KL-6 were 0.76 (95% confidence interval [CI]: 0.68-0.82) and 0.89 (95% CI: 0.83-0.93), whereas those for serum SP-D were 0.65 (95% CI: 0.45-0.80) and 0.88 (95% CI: 0.80-0.93). Comprehensive comparison of 2 circulating biomarkers using back-calculated likelihood ratio (LR) demonstrated that serum KL-6 corresponded to a higher LR+ and a lower LR- in comparison to serum SP-D, as well as in SSc-ILD. TSA indicated that evidence for serum KL-6 and SP-D in identifying CTD-ILD is powerful; nonetheless, more trials were needed for validation of serum KL-6 and SP-D in differentiating CTD-ILD subtypes, including different CTD and ethnicities. Conclusions: This meta-analysis suggested that serum KL-6 had superior diagnostic accuracy to SP-D for differentiating ILD from non-ILD among CTD patients, providing a convenient and non-invasive approach for screening and management of ILD among CTD patients.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据