期刊
MEASUREMENT SCIENCE AND TECHNOLOGY
卷 31, 期 9, 页码 -出版社
IOP PUBLISHING LTD
DOI: 10.1088/1361-6501/ab8dfb
关键词
stereo calibration; speckle-pattern calibration target; stereo-digital image correlation; inaccurate target
资金
- National Key Research and Development Program of China [2018YFB0703500]
- National Natural Science Foundation of China (NSFC) [11925202, 11872009, 11632010]
- Academic Excellence Foundation of BUAA for PhD Students
We describe an alternative stereo calibration method for stereo-digital image correlation (stereo-DIC) using computer-simulated speckle-pattern calibration targets and a DIC-based control points matching technique. The present work refines and extends the recently proposed camera calibration method to stereo calibration, which is an essential part of stereo-DIC measurement. In the proposed calibration method, the calibration target is generated by displaying a synthetic speckle pattern on a commercial tablet. On the simulated speckle pattern, a group of control points is specified with flexible location and number, which is further precisely matched to the captured calibration images using the well-developed subset-based DIC algorithm. These precisely matched control points are subsequently used to calibrate the intrinsic and extrinsic parameters of the stereo-DIC system with stereo calibration algorithm. For better accuracy, the error in the manufacture of the calibration target is also considered and compensated. As a flexible number of control point matches are registered with high accuracy and strong robustness, the presented stereo calibration method using synthetic speckle pattern calibration target offers higher calibration accuracy than that based on a calibration target with a limited number of designated features, such as checkerboard target and circular point target. After being demonstrated by a set of simulated calibration tests, the proposed stereo calibration method was applied to calibrate a real stereo-DIC system, which was then used to measure 3D full-field shapes and displacements. The results confirm the effectiveness and accuracy of the proposed stereo calibration method for stereo-DIC applications.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐
暂无数据