Early Diagnosis of Myocardial Infarction With Point-of-Care High-Sensitivity Cardiac Troponin I

期刊

JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY
卷 75, 期 10, 页码 1111-1124

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.jacc.2019.12.065

关键词

0/1-h algorithm; diagnosis of myocardial infarction; guidelines; high-sensitivity cardiac troponin I; point of care; rule in; rule out

资金

  1. Swiss National Science Foundation
  2. Swiss Heart Foundation
  3. Kommission fur Technologie und Innovation
  4. European Union
  5. Stiftung fur Kardiovaskulare Forschung Basel
  6. University of Basel
  7. University Hospital Basel
  8. Abbott
  9. Beckman Coulter
  10. Biomerieux
  11. Roche
  12. Ortho Clinical Diagnostics
  13. Quidel
  14. Siemens
  15. Singulex

向作者/读者索取更多资源

BACKGROUND Until now, high-sensitivity cardiac troponin (hs-cTn) assays were mainly developed for large central laboratory platforms. OBJECTIVES This study aimed to assess the clinical performance of a point-of-care (POC)-hs-cTnI assay in patients with suspected myocardial infarction (MI). METHODS This study enrolled patients presenting to the emergency department with symptoms suggestive of MI. Two cardiologists centrally adjudicated the final diagnosis using all clinical data including cardiac imaging. The primary objective was to directly compare diagnostic accuracy of POC-hs-cTnI-TriageTrue versus best-validated central laboratory assays. Secondary objectives included the derivation and validation of a POC-hs-cTnI-TriageTrue-specific 0/1-h algorithm. RESULTS MI was the adjudicated final diagnosis in 178 of 1,261 patients (14%). The area under the curve (AUC) for POC-hs-cTnI-TriageTrue at presentation was 0.95 (95% confidence interval [CI]: 0.93 to 0.96) and was at least comparable to hs-cTnT-Elecsys (AUC: 0.94; 95% CI: 0.93 to 0.96; p = 0.213) and hs-cTnI-Architect (AUC: 0.92; 95% CI: 0.90 to 0.93; p < 0.001). A single cutoff concentration <3 ng/l at presentation identified 45% of patients at low risk with a negative predictive value (NPV) of 100% (95% CI: 99.4% to 100%). A single cutoff concentration >60 ng/l identified patients at high risk with a positive predictive value (PPV) of 76.8% (95% CI: 68.9% to 83.6%). The 0/1-h algorithm ruled out 55% of patients (NPV: 100%; 95% CI: 98.8% to 100%), and ruled in 18% of patients (PPV: 76.8%; 95% CI: 67.2% to 84.7%). Ruled-out patients had cumulative event rates of 0% at 30 days and 1.6% at 2 years. This study confirmed these findings in a secondary analysis including hs-cTnI-Architect for central adjudication. CONCLUSIONS The POC-hs-cTnI-TriageTrue assay provides high diagnostic accuracy in patients with suspected MI with a clinical performance that is at least comparable to that of best-validated central laboratory assays. (Advantageous Predictors of Acute Coronary Syndromes Evaluation Study [APACE]; NCT00470587) (C) 2020 The Authors. Published by Elsevier on behalf of the American College of Cardiology Foundation.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据