Multiparametric Renal MRI: An Intrasubject Test-Retest Repeatability Study

期刊

JOURNAL OF MAGNETIC RESONANCE IMAGING
卷 53, 期 3, 页码 859-873

出版社

WILEY
DOI: 10.1002/jmri.27167

关键词

repeatability; reproducibility; kidney; MRI; multiparametric; functional

向作者/读者索取更多资源

The study assessed the intrasubject test-retest repeatability of renal MRI measurements in 19 healthy subjects, with most MRI measures showing good repeatability below 13%, except for perfusion fraction and perfusion as measured by DCE, which were above 13%.
Background: Renal multiparametric magnetic resonance imaging (MRI) is a promising tool for diagnosis, prognosis, and treatment monitoring in kidney disease. Purpose: To determine intrasubject test-retest repeatability of renal MRI measurements. Study Type: Prospective. Population: Nineteen healthy subjects aged over 40 years. Field Strength/Sequences: T-1 and T-2 mapping, R-2* mapping or blood oxygenation level-dependent (BOLD) MRI, diffusion tensor imaging (DTI), and intravoxel incoherent motion (IVIM) diffusion-weighted imaging (DWI), 2D phase contrast, arterial spin labelling (ASL), dynamic contrast enhanced (DCE) MRI, and quantitative Dixon for fat quantification at 3T. Assessment: Subjects were scanned twice with similar to 1 week between visits. Total scan time was similar to 1 hour. Postprocessing included motion correction, semiautomated segmentation of cortex and medulla, and fitting of the appropriate signal model. Statistical Test: To assess the repeatability, a Bland-Altman analysis was performed and coefficients of variation (CoVs), repeatability coefficients, and intraclass correlation coefficients were calculated. Results: CoVs for relaxometry (T-1, T-2, R-2*/BOLD) were below 6.1%, with the lowest CoVs for T-2 maps and highest for R-2*/BOLD. CoVs for all diffusion analyses were below 7.2%, except for perfusion fraction (FP), with CoVs ranging from 18-24%. The CoV for renal sinus fat volume and percentage were both around 9%. Perfusion measurements were most repeatable with ASL (cortical perfusion only) and 2D phase contrast with CoVs of 10% and 13%, respectively. DCE perfusion had a CoV of 16%, while single kidney glomerular filtration rate (GFR) had a CoV of 13%. Repeatability coefficients (RCs) ranged from 7.7-87% (lowest/highest values for medullary mean diffusivity and cortical FP, respectively) and intraclass correlation coefficients (ICCs) ranged from -0.01 to 0.98 (lowest/highest values for cortical FP and renal sinus fat volume, respectively). Data Conclusion: CoVs of most MRI measures of renal function and structure (with the exception of FP and perfusion as measured by DCE) were below 13%, which is comparable to standard clinical tests in nephrology.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据