4.5 Article

Optimum cold plasma generating device for treatment of Aspergillus flavus from nuts surface

期刊

JOURNAL OF FOOD SCIENCE AND TECHNOLOGY-MYSORE
卷 57, 期 11, 页码 3988-3994

出版社

SPRINGER INDIA
DOI: 10.1007/s13197-020-04429-y

关键词

Cold plasma devices; Aspergillus flavus; Nuts; Fungi reduction; Industrial relevance

向作者/读者索取更多资源

The objective of this research is to avail an optimum cold plasma generating device for inactivating Aspergillus flavus from nuts surface. For this purpose, a variety of tests were carried out using three applicable plasma generating devices such as atmospheric pressure capacitive coupled plasma (AP-CCP), direct current diode plasma (DC-DP), and inductively coupled plasma (ICP) for different values of input power, pressure, and irradiation time, using Argon gas. The experimental results were achieved upon performing irradiation of sample pistachio nuts by the aforementioned three devices. Finally, after data analysis based on two factors of toxin inactivation amount and cost feasibility for large scale industrial applications, the AP-CCP device was found to be as an optimum device with an acceptable 4 Logs fungi reduction. However, on the basis of single factor, i.e. toxin reduction rate, the DC-DP device works better with a highest fungi reduction rate of 5 Logs, using Argon in 1 Torr vacuum pressure, 300 W and 20 min irradiation.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据