4.6 Article

An improved recombinase polymerase amplification assay for visual detection of Vibrio parahaemolyticus with lateral flow strips

期刊

JOURNAL OF FOOD SCIENCE
卷 85, 期 6, 页码 1834-1844

出版社

WILEY
DOI: 10.1111/1750-3841.15105

关键词

false positive; isothermal amplification; lateral flow strip; rapid detection; recombinase polymerase amplification; Vibrio parahaemolyticus

向作者/读者索取更多资源

Vibrio parahaemolyticus is an important pathogenic bacterium in both food safety management and mariculture. Rapid and accurate detection technologies are critical for effective control of its outbreak and spreading. Conventional technologies and polymerase chain reaction (PCR)-based approaches have limited usage because of the requirement of laboratory instruments and trained personnel. Using the isothermal recombinase polymerase amplification (RPA) technology, several detection assays have been developed with added convenience. Combining the lateral flow strip (LFS) test with RPA can further simplify the detection. In this study, an improved RPA assay using LFS for visual detection of V. parahaemolyticus was developed. Primers were designed targeting the virulence genes and screened for amplification efficiency, nonspecific amplification, and primer-dimer formation. Probes were designed for the best primer pairs, and the weakness of LFS tests, being easily affected by primer-dependent artifacts, was overcome by sequence modifications on primers and probe. The RPA-LFS assay took 25 min at 35 to 45 degrees C, and showed excellent specificity. It detected as low as one colony forming unit (CFU) of V. parahaemolyticus per reaction without DNA purification, or 10 CFU/10 g spiked food samples with 2 hr of enrichment. The detection limit was better than the currently available RPA-based detection methods. Application of the RPA-LFS assay for simulated samples or real clinical samples showed accurate and consistent detection results compared to bioassay and quantitative PCR. The RPA-LFS assay provided a rapid, accurate, and convenient V. parahaemolyticus detection method suitable for on-site detection in resource-limited conditions. Practical Application This research developed a rapid and visual detection technology for Vibrio parahaemolyticus that is not dependent on complicated equipment. The detection process takes 25 min and the result is read with the naked eye. A detection kit can be developed based on this technology for on-site detection of V. parahaemolyticus in resource-limited regions for food safety management and mariculture.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据