4.6 Article

Heat transfer enhancement in pool boiling and condensation using h-BN/DCM and SiO2/DCM nanofluids: experimental and numerical comparison

出版社

EMERALD GROUP PUBLISHING LTD
DOI: 10.1108/HFF-02-2020-0113

关键词

Pool boiling; Nanofluid; Convective heat transfer enhancement; Hexagonal boron nitride; Silica; Computational fluid dynamics

向作者/读者索取更多资源

By adding nanoparticles to the base fluid, the thermal characteristics of the fluid were significantly increased. Experimental results showed that the heat transfer coefficient of h-BN/DCM nanofluid increased by 27.59%, 14.44%, and 15% for saturation boiling, after-saturation boiling, and condensation processes, respectively. This study provides a novel comparison of the effects of different nanoparticles on heat transfer for boiling-condensation processes with dichloromethane (DCM) fluid.
Purpose The purpose of this study is to experimentally and numerically scrutinize the heat transfer enhancement in pool boiling and condensation by changing the hydrophilicity or hydrophobicity properties of the working fluid, i.e. by use of nanofluid solution. Design/methodology/approach For specifying the effects of nanoparticle concentration on heat transfer properties, two different nanofluid solutions (h-BN/DCM and SiO2/DCM) at three different volumetric concentrations were prepared and tested under different heat flux conditions. Boiling curves, alterations in pressure with heat flux and heat transfer coefficients for both boiling and condensation processes were obtained and viscosity measurements were performed for dichloromethane (DCM) and each working fluid was prepared. In addition, a series of numerical simulations, via computational fluid dynamics approach, was performed for specifying the evaporation-condensation phenomena and temperature and velocity distributions. Findings Nanoparticle addition inside the base fluid increased the thermal characteristics of the base fluid significantly. For the experimental results of h-BN/DCM nanofluid, the increment rate in heat transfer coefficient for saturation boiling, after-saturation boiling and condensation processes was found as 27.59%, 14.44% and 15%, respectively. Originality/value The novelty of this comparison study is that there is no such experimental and numerical comparison study in literature for DCM fluid, which concentrates on thermal performance enhancement and compares the effect of different kinds of nanoparticles on heat transfer characteristics for boiling-condensation processes.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据