4.7 Article

High performance cooling of a HVDC converter using a fatty acid ester-based phase change dispersion in a heat sink with double-layer oblique-crossed ribs

期刊

INTERNATIONAL JOURNAL OF ENERGY RESEARCH
卷 44, 期 7, 页码 5819-5840

出版社

WILEY
DOI: 10.1002/er.5347

关键词

Euler-Euler multiphase modelling; fatty acid ester; HVDC converter cooling; multi-stream heat sink; oblique-crossed ribs; phase change dispersion

资金

  1. tate Grid Corporation of China
  2. Global Energy Interconnection Research Institute Europe GmbH [SGRIWLZXQT[2017]882]
  3. EPSRC [EP/L014211/1, EP/L019469/1, EP/S032622/1, EP/N021142/1, EP/N000714/1, EP/N001745/1, EP/J021199/1, EP/L017725/1, EP/N032888/1, EP/K002252/1] Funding Source: UKRI

向作者/读者索取更多资源

The paper concerns with a high performance cooling method for a HVDC converter using fatty acid ester-based phase change dispersion (PCD) in a heat sink with double-layer oblique-crossed ribs. Thermo-physical properties of PCDs were first characterized under both solid and liquid states, and the cooling performance of the heat exchanger was then experimentally examined, by heating two copper blocks clamped closely to the aluminium heating surfaces. A threedimensional Euler-Euler multiphase approach was further performed to evaluate the thermal performance under different operating conditions including heating power, flowrate and PCD concentration. The results showed that the viscosity of PCD can be a 100 times that of water, but the increased pumping power was only similar to 17.01% on average. The use of the PCD achieved a lower temperature of heat sink and fluid than that of water under the same set of conditions due to the latent heat of the PCM, thus enabling a safer and cooler environment for temperature-sensitive HVDC components such as insulated gate bipolar transistors (IGBT). An optimal set of working conditions was proposed and a flowrate of 8 L/min under a heating power of 1.1 kW and a PCM concentration of 25% was recommended for industrial cooling operations. Highlights A novel cooling method for HVDC converter using a fatty acid based PCD presented. A 3D Euler-Euler modelling performed and compared with experiments. Effects of operating conditions and PCM loading on cooling behaviour discussed. Three calculating methods of heat transfer coefficients compared. Optimal PCD cooling condition given based on overall performance evaluation.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据