4.7 Article

Three-level energy flexible management strategy for micro energy grids considering multiple uncertainties at different time scales

期刊

INTERNATIONAL JOURNAL OF ENERGY RESEARCH
卷 45, 期 1, 页码 316-341

出版社

WILEY
DOI: 10.1002/er.5479

关键词

capacity reconfiguration; demand response; flexible boundary; micro energy grid; three-level co-optimization

资金

  1. National Nature Science Foundation of China [71904049, 71874053, 71573084]
  2. Beijing Social Science Fund [18GLC058, 15JDJGD036]
  3. China Postdoctoral Science Foundation [2019M650024]
  4. 2018 Key Projects of Philosophy and Social Science Research, Ministry of Education, China [18JZD032]

向作者/读者索取更多资源

This paper presents a novel co-optimization model and algorithm for multiple micro energy grids, which can reduce reserve capacity, improve operational efficiency, and decrease investment costs.
This paper considers the co-optimization operation problem of the multiple micro energy grids (MEGs), and proposes a novel concept of the flexible boundary. Then, a three-level co-optimization model of reconfiguration, dispatching, and reserve is designed considering different time scales. Furthermore, an improved ant colony algorithm based on the information entropy and the chaotic search is proposed. The Shenzhen international low-carbon park in China is selected as an example. The results show that: (a) The capacity configuration scheme considering the flexible boundary conditions could decrease the reserve capacity of power, heating, and cooling from the upper energy grid, namely, 75%, 50%, and 75%, and delay 537 x 10(4) yen the investment cost of the new capacity by utilizing the complementary characteristics between different MEGs. (b) The proposed three-level co-optimization model could establish the multi-level optimal cooperative operation schemes of multi-MEGs and decrease the reserve power from the upper energy grid and incentive-based demand response. Among them, UPG provides MEG 1, MEG 2, and MEG 3 with cooling load reserve capacity reduction of 53.95, 85.44, and 38.3 kw h. The positive reserve provided by IBDR for MEG 1, MEG 2, and MEG 3 decreased by 30.53, 20.21, and 52 kW h. (c) The proposed improved ant colony algorithm can consider the operational characteristics of each energy entity in different stages of multi-MEGs and obtain the global optimal operation scheme. Compared the traditional ant colony algorithm, the average convergence times decrease by 18% and the optimization degree of the objective value increase by 12.38%. (d) The sensitivity analysis shows the conditional value at risk method can formulate the optimal dispatching schemes of multi-MEGs according to the risk attitudes of decision makers. When confidence degree is between 0.3 and 0.8, the decision-makers have a high-risk sensitivity and are more willing to avoid uncertain risks of wind power plant and photovoltaic power. Overall, the proposed model and solution algorithm could achieve the optimal operation strategy of the micro energy grids.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据