4.5 Article

On-site measurement and simulation of indoor particulate matter distributed in a single room with stratified flow field

期刊

INDOOR AND BUILT ENVIRONMENT
卷 30, 期 7, 页码 886-905

出版社

SAGE PUBLICATIONS LTD
DOI: 10.1177/1420326X20919788

关键词

Indoor air quality; Particulate matter; On-site measurement; Model simulation; Stratified distribution

向作者/读者索取更多资源

This study used on-site measurement and model simulation to characterize the spatial distribution of indoor particulate matter in a single room with stratified flow fields. It revealed that fine particles accounted for a large percentage of total PM emissions. The results provide crucial information for determining indoor PM monitoring sites.
This study combined on-site measurement and model simulation to characterize the spatial distribution of indoor particulate matter (PM) in a single room with stratified flow fields. The concentration of PM spatially distributed in a single room with natural ventilation was measured at different heights for different PM sizes. This study revealed that the PM concentration varied with height and time. Moreover, chamber test results showed that by burning Chinese worship incense, fine particles (PM0-4) accounted for 97.33% of total PM with an average emission factor of 39.54 mg/g. The results were then applied to determine the gross emission of PM and describe its spatial distribution in a single room. Model simulation results indicated that only a small amount of PM flowed out of the room due to the trap by an indoor vortex under natural ventilation. The results are crucial for characterizing the stratified PM concentration and determining the sites for PM monitoring in indoor environments.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据