期刊
IEEE TRANSACTIONS ON POWER ELECTRONICS
卷 35, 期 5, 页码 4971-4983出版社
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TPEL.2019.2941957
关键词
DC link; doubly fed induction generator (DFIG); multiple reference frame; torque ripple mitigation
In this article, a multiple reference frame (MRF)-based approach is proposed to mitigate the torque ripple of the DFIG-dc system. The DFIG-dc system uses a diode bridge rectifier between the stator winding of DFIG and dc link. A reduced-power three-phase pulsewidth modulation converter is connected between the rotor winding of DFIG and dc link. Due to the diode commutation, the stator current and stator flux linkage are distorted with harmonics. To reduce the resulting torque ripple, the rotor currents need to track a pulsating reference signal to compensate the distortion of the stator flux. To improve the current tracking performance, MRF-based estimators are used to calculate the main harmonics in both the command value and actual value of the rotor current. Then, an MRF-based regulator is implemented to achieve an accurate tracking for the harmonics of the rotor current command. Both simulation and experimental results demonstrate the effectiveness of the proposed scheme in reducing the torque ripple. The robustness of the proposed algorithm against deviation of stator frequency is also supported by the simulation and experimental results.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐
暂无数据