There is a lack of data and guidance on soft exoskeleton pressure contact with the body. The purpose of this research was to study the relationship between circumferential loading at the knee and discomfort/pain, to inform the design of soft exoskeletons/exosuits. The development of discomfort and pain was studied during standing and walking with circumferential compression using a pneumatic cuff. Our results show higher tolerance for intermittent than continuous compression during standing. Discomfort was triggered at pressures ranging from 13.7 kPa (continuous compression) to 30.4 kPa (intermittent compression), and pain at 52.9 kPa (continuous compression) to 60.6 kPa (intermittent compression). During walking, cyclic compression caused an increase in discomfort with time. Higher cuff inflation pressures caused an earlier onset and higher end intensities of discomfort than lower pressures. Cyclic cuff inflation of 10 kPa and 20 kPa was reasonably well tolerated. Practitioner summary Soft exoskeleton compression of the knee was simulated during static and dynamic compression cycles. The results can be used to understand how users tolerate pressure at the knee, and also to understand the levels at which discomfort and pain are experienced.