4.2 Article

First catheter-based high-density endocardial 3D electroanatomical mapping of the right atrium in standing horses

期刊

EQUINE VETERINARY JOURNAL
卷 53, 期 1, 页码 186-193

出版社

WILEY
DOI: 10.1111/evj.13265

关键词

horse; atrial arrhythmia; high-density endocardial mapping; 3D electroanatomical mapping; HD Grid

资金

  1. Novo Nordisk Foundation
  2. Danish Research Council (DFF) [8020-00415B]

向作者/读者索取更多资源

The study describes the use of high-density three-dimensional electroanatomical mapping in standing horses to provide detailed information about activation patterns and electrogram characteristics in the right atrium.
Background Three-dimensional electroanatomical mapping is of potential interest in equine cardiology to identify arrhythmia mechanisms, characterise electroanatomical substrates and guide ablation strategies. Objectives To describe three-dimensional electroanatomical mapping in standing horses. Study design Research methodology, proof of concept study. Methods Four Standardbred horses (2 geldings, 2 mares, median age 4.5 [4-9] years, mean bodyweight 485 [440-550] kg) were sedated and placed in stocks. Via the jugular vein, a high-density multipolar grid catheter (Advisor((TM)) HD Grid Mapping Catheter with EnSite VelocityTM, Abbott Medical) was used for endocardial mapping of the right atrium. The P-wave on the surface ECG was used as a timing reference for simultaneous local activation time- and bipolar voltage-mapping. For a positional reference a 10-pole catheter (Abbott Medical) was placed in the caudal vena cava. Results Endocardial right atrial mapping guided by the three-dimensional mapping system and local electrograms was successfully performed in all four horses. A median of 32719 [25499-65078] points, covering the entire right atrium, were collected. Three-dimensional electroanatomical mapping provided detailed information about activation patterns and electrogram-characteristics of the sinoatrial node, intervenous tubercle and cavotricuspid isthmus. Additionally, transvenous biopsy forceps connected to the mapping system were visualised on screen to guide biopsy collection. Main limitations The feasibility of electroanatomical mapping for the left atrium and in larger breeds requires further study. Conclusions High-density three-dimensional electroanatomical mapping of the right atrium is feasible in the standing horse.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.2
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据