4.5 Article

Single-Cell Tests to Explore the Reliability of Sofc Installations Operating Offshore

期刊

ENERGIES
卷 13, 期 7, 页码 -

出版社

MDPI
DOI: 10.3390/en13071624

关键词

SOFC; reliability; contamination; salt; oxygen starvation; concentration polarization

资金

  1. Gassnova grant [CHEOP-CC616060]
  2. Norwegian Research Council [CHEOP 245489/E30]

向作者/读者索取更多资源

This paper studies the robustness of off-shore solid oxide fuel cell (SOFC) installations and the nature and causes of possible cell degradation in marine environments. Two important, cathode-related, impediments to ensuring SOFC reliability in off-shore installations are: cathode degradation due to salt contamination and oxygen depletion in the air supply. Short-term and long-term tests show the effect of salt contamination in the cathode feed on cell performance, and reveal the underlying cause of the degradation seen. SEM/X-ray Diffraction /(XRD) analyses made it possible to identify salt taken up in the cathode microstructure after the short-term testing while the macroscopic cell structure remained intact after the short-term tests. The long-term degradation was found to be more severe, and SEM images showed delamination at the cathode/electrolyte interface with salt present, something that was not seen after long-term testing without salt. The effect of oxygen depletion on the performance was also determined at three different temperatures using I-V curves.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分