4.5 Article

An adaptive workload-aware power consumption measuring method for servers in cloud data centers

期刊

COMPUTING
卷 105, 期 3, 页码 515-538

出版社

SPRINGER WIEN
DOI: 10.1007/s00607-020-00819-4

关键词

Cloud server; Power measurement; Power model; Workload classification; Workload-aware

向作者/读者索取更多资源

As cloud computing technologies continue to advance, the issue of excessive energy consumption in cloud datacenters has become a widespread concern. To address this issue, we propose separate power consumption models based on workload types and an adaptive workload-aware power consumption measuring method. The method accurately predicts future workloads and selects the appropriate power model, reducing real-time power estimation lag.
As cloud computing technologies and applications develop rapidly in recent years, the quantity and size of cloud datacenters have been ever-increasing, making the overconsumption of energy in datacenters become a widespread concern. To reduce the energy cost by servers, we must first build an accurate power model to achieve flexible, device-free power consumption measuring. However, most of the previous work related to server power modeling solely apply to the server and virtual machine levels, and the existing power models fail to take into account the heterogeneity in workload. Therefore, we first propose separate power consumption models based on the distinction of workload types including CPU-intensive, I/O-intensive, memory-intensive, and mixed workload. Then, we present an adaptive workload-aware power consumption measuring method (WSPM) for cloud servers. Our method proactively selects an appropriate power model for the upcoming workload through workload clustering, forecasting and classification, which are implemented using K-means, ARIMA, and threshold-based methods, respectively. We conducted several experiments to evaluate the performance of the key components of our method. The result shows: (1) the accuracy of our future workload forecasting on real traces of requests to our servers, (2) the accuracy of the power consumption measured by WSPM, and (3) the effectiveness of our workload-aware method in reducing real-time power estimation lag. Overall, the proposed method simplifies power modeling under diverse workloads without losing accuracy, making it a general and highly available solution for cloud data centers.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据