4.7 Article

Antibody Responses to SARS-CoV-2 in Patients With Novel Coronavirus Disease 2019

期刊

CLINICAL INFECTIOUS DISEASES
卷 71, 期 16, 页码 2027-2034

出版社

OXFORD UNIV PRESS INC
DOI: 10.1093/cid/ciaa344

关键词

antibody; SARS-CoV-2; COVID-19

资金

  1. Bill & Melinda Gates Foundation
  2. Office Of The Director
  3. Office of Integrative Activities [1317771, GRANTS:13630810] Funding Source: National Science Foundation
  4. National Research Foundation of Korea [5199991714317, 4120200713815, 2011-0014198] Funding Source: Korea Institute of Science & Technology Information (KISTI), National Science & Technology Information Service (NTIS)
  5. Russian Science Foundation [14-15-00615, 20-44-07001, 16-15-00157, 20-42-09035, 15-15-00135, 17-23-00013] Funding Source: Russian Science Foundation

向作者/读者索取更多资源

Background. The novel coronavirus SARS-CoV-2 is a newly emerging virus. The antibody response in infected patients remains largely unknown, and the clinical value of antibody testing has not been fully demonstrated. Methods. 173 patients with SARS-CoV-2 infection were enrolled. Their serial plasma samples (n = 535) collected during hospitalization were tested for total antibodies (Ab), IgM, and IgG against SARS-CoV-2. The dynamics of antibodies with disease progress were analyzed. Results. Among 173 patients, the seroconversion rates for Ab, IgM, and IgG were 93.1%, 82.7%, and 64.7%, respectively. The reason for the negative antibody findings in 12 patients might be due to the lack of blood samples at the later stage of illness. The median seroconversion times for Ab, IgM, and then IgG were days 11, 12, and 4, respectively. The presence of antibodies was <40% among patients within 1 week of onset, and rapidly increased to 100.0% (Ab), 94.3% (IgM), and 79.8% (IgG) by day 15 after onset. In contrast, RNA detectability decreased from 66.7% (58/87) in samples collected before day 7 to 45.5% (25/55) during days 15-39. Combining RNA and antibody detection significantly improved the sensitivity of pathogenic diagnosis for COVID-19 (P < .001), even in the early phase of 1 week from onset (P = .007). Moreover, a higher titer of Ab was independently associated with a worse clinical classification (P = .006). Conclusions. Antibody detection offers vital clinical information during the course of SARS-CoV-2 infection. The findings provide strong empirical support for the routine application of serological testing in the diagnosis and management of COVID-19 patients.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据