4.3 Article

Italian Multicenter Registry of Bare Metal Stent Use in Modern Percutaneous Coronary Intervention Era (AMARCORD): A multicenter observational study

期刊

出版社

WILEY
DOI: 10.1002/ccd.28798

关键词

bare metal stent; bleeding; coronary artery disease; drug-eluting stent; dual antiplatelet therapy; percutaneous coronary intervention

资金

  1. Boston Scientific

向作者/读者索取更多资源

The study demonstrated a progressive decrease in the use of bare metal stents over the past 5 years, with main reasons for implantation being ST-elevation myocardial infarction, advanced age, and perceived high-bleeding risk by physicians. High rates of mortality and MACE were observed in this high-risk population.
Objectives We aimed to evaluate the use of bare metal stent (BMS) implantation in current percutaneous coronary intervention (PCI) era, focusing on indications for use and clinical outcomes. Background Limited data on BMS usage in current clinical practice are available. Methods All patients who underwent PCI with at least one BMS implantation in 18 Italian centers from January 1, 2013 to December 31, 2017, were included in our registry. Rates of BMS use and reasons for BMS implantations were reported for the overall study period and for each year. Primary outcomes were mortality, bleeding (Bleeding Academic Research Consortium-BARC and Thrombolysis in Myocardial Infarction-TIMI non-CABG definitions), and major adverse cardiac events (MACE) defined as the composite of all-cause and cardiac death, any myocardial infarction, target vessel revascularization, or any stent thrombosis. Results Among 58,879 patients undergoing PCI in the study period, 2,117 (3.6%) patients (mean age 73 years, 69.7% males, 73.3% acute coronary syndrome) were treated with BMS implantation (2,353 treated lesions). The rate of BMS implantation progressively decreased from 10.1% (2013) to 0.3% (2017). Main reasons for BMS implantation were: ST-elevation myocardial infarction (STEMI) (23.1%), advanced age (24.4%), and physician's perception of high-bleeding risk (34.0%). At a mean follow-up of 2.2 +/- 1.5 years, all-cause and cardiac mortality were 25.6 and 12.7%, respectively; MACE rate was 35.3%, any bleeding rate was 13.0% (BARC 3-5 bleeding 6.3%, TIMI non-CABG major bleeding 6.1%). Conclusion In a large, contemporary, real-world, multicenter registry, BMS use progressively reduced over the last 5 years. Main reasons for BMS implantation were STEMI, advanced age, and physician's perception of high-bleeding risk. High rates of mortality and MACE were observed in this real-world high-risk population.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据