4.6 Article

Using incognito standardised patients to evaluate quality of eye care in China

期刊

BRITISH JOURNAL OF OPHTHALMOLOGY
卷 105, 期 3, 页码 311-316

出版社

BMJ PUBLISHING GROUP
DOI: 10.1136/bjophthalmol-2019-315103

关键词

optics and refraction; diagnostic tests; investigation; public health; treatment other

资金

  1. Ministry of Education's 111 Project [B16031]
  2. Ulverscroft Foundation (UK)

向作者/读者索取更多资源

This study objectively assessed the quality of eye care in Northwestern China using the incognito standardized patient approach, finding that inaccurate refractions are common in public facilities and important assessments are frequently omitted.
Background/aims Few studies have objectively examined the quality of eye care in China. We assessed refractive care using the incognito standardised patient (SP) approach, a gold standard for evaluating clinical practice. Methods A total of 52 SPs were trained to provide standardised responses during eye examinations, and underwent automated and non-cycloplegic, subjective refraction by a senior ophthalmologist from Zhongshan Ophthalmologic Center, a national-level clinical and research centre. SPs subsequently received subjective refraction and eye exams at a randomly selected sample of 40 public hospitals and 93 private optical shops in Shaanxi, Northwestern China. Difference between expert and local refraction in the better-seeing eye was calculated by the vector diopteric method, and completeness of exams assessed against national standards. SP and provider demographic information and provider clinical experience were recorded. Results SPs (n=52, mean (range) age, 25.7 (22-31) years, 28.8% male) underwent 133 eye exams (mean total duration 15.0 +/- 11.7 min) by 133 local refractionists (24-60 years, 30.3% male). Only 93 (69.9%), 121 (91.0%) and 104 (78.2%) of local refractionists assessed vision, automated and subjective refraction, respectively. The median inaccuracy was -0.25 diopters (D), while 25.6% of results differed by an absolute value of >= 1.0 D and 6.0% by >= 2.0 D. Predictors of inaccurate refraction included spectacle power <-6.0 D (OR=2.66; 95% CI, 1.27 to 5.56), service at a public (vs private) hospital (OR=2.01; 95% CI, 1.11 to 3.63) and provider male sex (OR=2.03; 95% CI, 1.11 to 3.69). Conclusion Inaccurate refractions are common in Northwestern China, particularly in public facilities. Important assessments, including subjective refraction, are frequently omitted.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据