4.7 Article

Reagent-free total protein quantification of intact extracellular vesicles by attenuated total reflection Fourier transform infrared (ATR-FTIR) spectroscopy

期刊

ANALYTICAL AND BIOANALYTICAL CHEMISTRY
卷 412, 期 19, 页码 4619-4628

出版社

SPRINGER HEIDELBERG
DOI: 10.1007/s00216-020-02711-8

关键词

Extracellular vesicle (EV); Infrared spectroscopy; Protein quantification; ATR-FTIR; Chemometrics

资金

  1. Research Centre for Natural Sciences
  2. National Research, Development and Innovation Office NKFIH, Hungary [NVKP_16-1-2016-0007, PD 121326, PD 124451, K 131594, K 119269]
  3. Janos Bolyai Research Scholarship of the Hungarian Academy of Sciences
  4. New National Excellence Program of the Ministry for Innovation and Technology [UNKP-19-3]

向作者/读者索取更多资源

Extracellular vesicles (EVs) are lipid bilayer-bounded particles that are actively synthesized and released by cells. The main components of EVs are lipids, proteins, and nucleic acids and their composition is characteristic to their type and origin, and it reveals the physiological and pathological conditions of the parent cells. The concentration and protein composition of EVs closely relate to their functions; therefore, total protein determination can assist in EV-based diagnostics and disease prognosis. Here, we present a simple, reagent-free method based on attenuated total reflection Fourier transform infrared (ATR-FTIR) spectroscopy to quantify the protein content of EV samples without any further sample preparation. After calibration with bovine serum albumin, the protein concentration of red blood cell-derived EVs (REVs) were investigated by ATR-FTIR spectroscopy. The integrated area of the amide I band was calculated from the IR spectra of REVs, which was proportional to the protein quantity in the sample, regardless of its secondary structure. A spike test and a dilution test were performed to determine the ability to use ATR-FTIR spectroscopy for protein quantification in EV samples, which resulted in linearity with R-2 values as high as 0.992 over the concentration range of 0.08 to 1 mg/mL. Additionally, multivariate calibration with the partial least squares (PLS) regression method was carried out on the bovine serum albumin and EV spectra. R-2 values were 0.94 for the calibration and 0.91 for the validation set. The results indicate that ATR-FTIR measurements provide a reliable method for reagent-free protein quantification of EVs.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据