4.7 Article

Cost effectiveness of reinforcement alternatives for a concrete water chlorination tank

期刊

JOURNAL OF BUILDING ENGINEERING
卷 27, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.jobe.2019.100992

关键词

Life-cycle cost analysis; Sustainable concrete; Corrosion; Stainless steel reinforcement; GFRP reinforcement

资金

  1. Qatar National Research Fund, Qatar (Qatar Foundation) [NPRP 9-110-2-052]

向作者/读者索取更多资源

Reinforced concrete tanks in water/wastewater treatment plants are susceptible to severe corrosion due to aggressive exposure conditions resulting from the application of certain treatment chemicals and methods. Noncorrosive materials, such as stainless steel or fiber reinforced polymer (FRP), may be attractive alternative reinforcement options for such concrete structures. However, the high initial cost of such materials imposes constraints on their use, although such thinking ignores improvements in long-term concrete durability. The current paper addresses the use of non-corrosive reinforcement in a concrete water chlorination tank using lifecycle cost analysis (LCCA) that aims to evaluate the cost effectiveness of different reinforcement alternatives. A comparison was established between four concrete reinforcing materials, namely, black steel, epoxy coated steel, stainless steel, and glass-FRP (GFRP) through a 100-year analysis period. The results of this study suggest that the use of non-corrosive reinforcement helps achieve a considerable long-term cost saving. LCCA showed that GFRP becomes more economical than black steel in 35 years following construction. The net present cost (NPC) obtained for the GFRP-reinforced concrete was approximately 43% lower than that of the black steel reinforced concrete. The use of stainless steel also had a potential advantage but was less cost-effective than GFRP, with a 50-year payback period and an NPC 25% lower than that of the conventional design. Epoxy coated steel also showed a long-term cost benefit when compared to black steel, with approximately 11% reduction in NPC and 15-year extension in the service life. Sensitivity analyses were performed to assess the effects of the analysis period, discount rate, construction costs, concrete strength, and the use of supplementary cementitious materials on the LCCA outcomes.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据