4.4 Article

Low-dose and sparse sampling MDCT-based femoral bone strength prediction using finite element analysis

期刊

ARCHIVES OF OSTEOPOROSIS
卷 15, 期 1, 页码 -

出版社

SPRINGER LONDON LTD
DOI: 10.1007/s11657-020-0708-9

关键词

Finite element analysis; Proximal femur; Multi-detector computed tomography; Statistical iterative reconstruction; Bone strength; Sparse sampling; Osteoporosis

资金

  1. Deutsche Forschungsgemeinschaft (DFG, German Research Foundation) [432290010]

向作者/读者索取更多资源

This study aims to evaluate the impact of dose reduction through tube current and sparse sampling on multi-detector computed tomography (MDCT)-based femoral bone strength prediction using finite element (FE) analysis. FE-predicted femoral failure load obtained from MDCT scan data was not significantly affected by 50% dose reductions through sparse sampling. Further decrease in dose through sparse sampling (25% of original projections) and virtually reduced tube current (50% and 25% of the original dose) showed significant effects on the FE-predicted failure load results. Purpose To investigate the effect of virtually reduced tube current and sparse sampling on multi-detector computed tomography (MDCT)-based femoral bone strength prediction using finite element (FE) analysis. Methods Routine MDCT data covering the proximal femur of 21 subjects (17 males; 4 females; mean age, 71.0 +/- 8.8 years) without any bone diseases aside from osteoporosis were included in this study. Fifty percent and 75% dose reductions were achieved by virtually reducing tube current and by applying a sparse sampling strategy from the raw image data. Images were then reconstructed with a statistically iterative reconstruction algorithm. FE analysis was performed on all reconstructed images and the failure load was calculated. The root mean square coefficient of variation (RMSCV) and coefficient of correlation (R-2) were calculated to determine the variation in the FE-predicted failure load data for dose reductions, using original-dose MDCT scan as the standard of reference. Results Fifty percent dose reduction through sparse sampling showed lower RMSCV and higher correlations when compared with virtually reduced tube current method (RMSCV = 5.70%, R-2 = 0.96 vs. RMSCV = 20.78%, R-2 = 0.79). Seventy-five percent dose reduction achieved through both methods (RMSCV = 22.38%, R-2 = 0.80 for sparse sampling; RMSCV = 24.58%, R-2 = 0.73 for reduced tube current) could not predict the failure load accurately. Conclusion Our simulations indicate that up to 50% reduction in radiation dose through sparse sampling can be used for FE-based prediction of femoral failure load. Sparse-sampled MDCT may allow fracture risk prediction and treatment monitoring in osteoporosis with less radiation exposure in the future.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据