4.2 Article

Effect of Switching from a Progestin-Primed Ovarian Stimulation Protocol to a Modified Ultra-Long Protocol Among Women Who Had 1 Progestin-Primed Ovarian Stimulation (PPOS) Failure Verses Those Who Had 2 PPOS Failures

期刊

MEDICAL SCIENCE MONITOR
卷 26, 期 -, 页码 -

出版社

INT SCIENTIFIC INFORMATION, INC
DOI: 10.12659/MSM.918705

关键词

Embryonic Development; Fertilization In Vitro; Medroxyprogesterone; Ovulation Induction

资金

  1. National Key Project of China [SQ2018YFC1003000]
  2. National Natural Science Foundation of China [81771533, 81571397]

向作者/读者索取更多资源

Background: There is little research on whether normoresponsive patients who produced poor-quality embryos once verses those who produced poor-quality embryos twice when using a single COH protocol should change to a different controlled ovarian hyperstimulation (COH) protocol. Material/Methods: In this retrospective study, we enrolled 108 patients with 1 PPOS failure who chose to continue receiving the progestin-primed ovarian stimulation (PPOS) protocol (n=61) versus those who decided to switch to the modified ultra-long protocol (n=47). We also enrolled 131 normoresponsive patients with 2 PPOS failures who chose to continue receiving the PPOS protocol (n=60) versus those who decided to switch to the modified ultra-long protocol (n=71) in the third cycle. Results: We found no significant difference in clinical outcomes of patients with 1 PPOS failure who continued using the PPOS protocol verses those who switched to the modified ultra-long protocol in the second cycle, expect for a lower cancelation rate (4.3% vs. 16.4%). However, the patients with 2 PPOS failures had significantly more good-quality embryos (0.9 vs. 0.4), more viable embryos (1.8 vs. 0.9), lower cancelation rates (18.3% vs. 53.3%), and higher pregnancy rates per aspirated cycle (26.8% vs. 10.0%) when switching to the modified ultra-long protocol compared to those who decided to continue receiving the PPOS protocol (P<0.05). Furthermore, the odds of clinical pregnancy (odds ratio [OR] 5.997, 95% confidence interval [CI] 1.476-24.361, P=0.01) were positively associated with switching to the COH protocol in the third cycle. Conclusions: For normoresponsive patients with poor-quality embryos when using the PPOS protocol, switching to the modified ultra-long protocol after having 2 PPOS failures was associated with better ART outcomes.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.2
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据